JELD-WEN, inc. engineered the Siteline Clad Wood (W-5500) Fixed Direct Set Geo Picture Window line for Northern, North-Central, South-Central, Southern, certifying 4,582 glass-spacer combinations from 0.14 to 0.32 U-Factor and 0.13 to 0.57 SHGC. Relative to other Wood models tracked under NFRC JEL, its minimum U-Factor is 0.07 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.14
- SHGC Range
- 0.13-0.57
- Certified Options
- 4,582
- Category Standing
- #72 of 1,352
How does JELD-WEN, inc. Siteline Clad Wood (W-5500) Fixed Direct Set Geo compare thermally against Window peers?
JELD-WEN, inc. Siteline Clad Wood (W-5500) Fixed Direct Set Geo achieves a 0.14 thermal floor across Window lines, placing #72 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Relative to Window assemblies nationwide (median U 0.20), Siteline Clad Wood (W-5500) Fixed Direct Set Geo is 0.06 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.14-0.32.
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 394 configurations meet ENERGY STAR Most Efficient criteria while 816 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-10-11. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.14 conducts 84.0 BTU/hr (-48.0 BTU/hr vs the 0.22 ceiling).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 4,582 certified glazing combinations for Siteline Clad Wood (W-5500) Fixed Direct Set Geo (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 816 packages (282 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 784 packages (132 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 2,073 packages (13 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 3,692 packages (125 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Weather Shield Mfg., Inc. — 630 Wood Direct Set | Wood | 0.14 | 0.13 | 5,555 |
| Kolbe and Kolbe Millwork Co., Inc — Ultra Push-Out Casement Picture | Wood | 0.14 | 0.10 | 2,719 |
| Kolbe and Kolbe Millwork Co., Inc — Ultra Casement_Sliding Door Transom Sash Set | Wood | 0.14 | 0.09 | 1,868 |
| Sierra Pacific Windows — Clad Aspen Fixed | Wood | 0.14 | 0.10 | 1,585 |
| Andersen Corporation — Complementary Wood Specialty Windows - Direct-Set | Wood | 0.14 | 0.14 | 7,588 |
What other certified series does JELD-WEN, inc. produce?
Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
7500 Series Horizontal Slider
U-Factor 0.14–0.32 · 42,001 certified options.
Premium Vinyl (V-4500) Casement Fixed Direct Set
U-Factor 0.14–0.32 · 2,573 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Siteline Clad Wood (W-5500) Fixed Direct Set Geo appear below.
What thermal performance numbers separate JELD-WEN, inc. Siteline Clad Wood (W-5500) Fixed Direct Set Geo from peers?
Built with Wood framing in Fixed Window (FIXD) style, JELD-WEN, inc. Siteline Clad Wood (W-5500) Fixed Direct Set Geo offers 4,582 Version 7.0 configurations from U 0.14 up to 0.32, posting -0.06 against the Window median of 0.20 with 394 Most Efficient picks.
How does JELD-WEN, inc. Siteline Clad Wood (W-5500) Fixed Direct Set Geo satisfy Version 7.0 Northern criteria?
Yes, 816 packages satisfy Northern ENERGY STAR Version 7.0 rules in Siteline Clad Wood (W-5500) Fixed Direct Set Geo. Pairing multi-pane insulation down to 0.14 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.
What conductive BTU/hr difference separates Siteline Clad Wood (W-5500) Fixed Direct Set Geo from the 0.22 Northern rule?
At U 0.14, a standard 3x5 ft (15 sq ft) Siteline Clad Wood (W-5500) Fixed Direct Set Geo opening transfers 84.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -48.0 BTU/hr difference.
What are the practical limitations of specifying Siteline Clad Wood (W-5500) Fixed Direct Set Geo?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Siteline Clad Wood (W-5500) Fixed Direct Set Geo options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
Can you install JELD-WEN, inc. Siteline Clad Wood (W-5500) Fixed Direct Set Geo in Southern or South-Central zones?
Across Northern, North-Central, South-Central, Southern, 3,692 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside JELD-WEN, inc. Siteline Clad Wood (W-5500) Fixed Direct Set Geo, while total line SHGC reaches 0.57 in colder packages.
Are all 4,582 Siteline Clad Wood (W-5500) Fixed Direct Set Geo configurations ENERGY STAR Most Efficient?
No. Exactly 394 of 4,582 configurations (8.6%) earn ENERGY STAR Most Efficient status in Siteline Clad Wood (W-5500) Fixed Direct Set Geo; the remaining standard v7.0 options pass base zone limits only.
What 2026 federal tax credit and Lead RRP rules apply to Siteline Clad Wood (W-5500) Fixed Direct Set Geo?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 JELD-WEN, inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
Where are NFRC and IGCC identification marks located on Siteline Clad Wood (W-5500) Fixed Direct Set Geo?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code JEL and product line JEL-N-889, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Siteline Clad Wood (W-5500) Fixed Direct Set Geo come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)