Window · Wood Frame NFRC AND · Product Line AND-N-106 ENERGY STAR Most Efficient Eligible

Andersen Corporation — Complementary Wood Specialty Windows - Direct-Set · Picture Window

Andersen Corporation Complementary Wood Specialty Windows - Direct-Set is a Picture Window assembly with a Wood frame that reaches a minimum U-Factor of 0.14 across 7,588 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #72 of 1,352 in Window, its thermal floor is 0.06 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.14 to 0.56.

Min U-Factor
0.14
SHGC Range
0.14-0.56
Certified Options
7,588
Category Standing
#72 of 1,352

How does Andersen Corporation Complementary Wood Specialty Windows - Direct-Set compare thermally against Window peers?

Andersen Corporation Complementary Wood Specialty Windows - Direct-Set achieves a 0.14 thermal floor across Window lines, placing #72 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Complementary Wood Specialty Windows - Direct-SetHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing Complementary Wood Specialty Windows - Direct-Set (U 0.14).249<=0.15This model: U 0.143140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Complementary Wood Specialty Windows - Direct-Set Cohort StandingMin U-Factor 0.14 stands at rank #72 of 1,352, outperforming 90.0% of peers.Min U-Factor 0.14Rank #72 of 1,352 (90.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Wood cohort (0.21 median U-Factor), Complementary Wood Specialty Windows - Direct-Set reaches 0.14 on its lowest-conductivity package — #23 of 408 in Wood, tied with 10 others at 0.14, more insulating than 91.9% of Wood lines, top 8.1% (-0.07 vs Wood peers). Pairing NFRC ID AND across multi-pane fills shifts U-Factor from 0.32 down toward 0.14.

Mapping NFRC SHGC values (0.14 to 0.56) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 1,872 configurations meet ENERGY STAR Most Efficient criteria while 2,329 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors AND to 2026-03-12 certification (FENSTAR issued 2019-01-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 84.0 BTU/hr conductive loss (-36.4% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 7,588 certified glazing combinations for Complementary Wood Specialty Windows - Direct-Set (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 2,329 packages (900 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 2,992 packages (1,468 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 3,521 packages (840 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 5,688 packages (1,080 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation Complementary Wood Specialty Windows - Direct-Set appear below.

What U-Factor and SHGC range does Andersen Corporation Complementary Wood Specialty Windows - Direct-Set achieve?

Across 7,588 tested NFRC glazing configurations, Andersen Corporation Complementary Wood Specialty Windows - Direct-Set with Wood framing and Fixed Window (FIXD) style reaches a 0.14 minimum U-Factor and 0.14-0.56 SHGC band. It places #72 among 1,352 Window series—top 10.0%.

Does Andersen Corporation Complementary Wood Specialty Windows - Direct-Set qualify for the ENERGY STAR Northern Zone?

Cold-climate buyers get 2,329 compliant Northern packages inside Complementary Wood Specialty Windows - Direct-Set, reaching down to U 0.14. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

What BTU/hr heat transfer results from Complementary Wood Specialty Windows - Direct-Set's 0.14 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Complementary Wood Specialty Windows - Direct-Set at U 0.14 conducts 84.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What are the practical limitations of specifying Complementary Wood Specialty Windows - Direct-Set?

Skip Complementary Wood Specialty Windows - Direct-Set if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Complementary Wood Specialty Windows - Direct-Set options exceeding U 0.22.

Can you install Andersen Corporation Complementary Wood Specialty Windows - Direct-Set in Southern or South-Central zones?

Across Northern, North-Central, South-Central, Southern, 5,688 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Andersen Corporation Complementary Wood Specialty Windows - Direct-Set, while total line SHGC reaches 0.56 in colder packages.

How many Andersen Corporation Complementary Wood Specialty Windows - Direct-Set variants earn ENERGY STAR Most Efficient?

No. Exactly 1,872 of 7,588 configurations (24.7%) earn ENERGY STAR Most Efficient status in Complementary Wood Specialty Windows - Direct-Set; the remaining standard v7.0 options pass base zone limits only.

What federal compliance checks govern 2026 Complementary Wood Specialty Windows - Direct-Set window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Complementary Wood Specialty Windows - Direct-Set retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do you cross-check NFRC AND and product line AND-N-106 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-106 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation Complementary Wood Specialty Windows - Direct-Set come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros