Andersen Corporation — Complementary Wood Specialty Windows - Direct-Set · Picture Window
Andersen Corporation Complementary Wood Specialty Windows - Direct-Set is a Picture Window assembly with a Wood frame that reaches a minimum U-Factor of 0.14 across 7,588 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #72 of 1,352 in Window, its thermal floor is 0.06 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.14 to 0.56.
- Min U-Factor
- 0.14
- SHGC Range
- 0.14-0.56
- Certified Options
- 7,588
- Category Standing
- #72 of 1,352
How does Andersen Corporation Complementary Wood Specialty Windows - Direct-Set compare thermally against Window peers?
Andersen Corporation Complementary Wood Specialty Windows - Direct-Set achieves a 0.14 thermal floor across Window lines, placing #72 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Wood cohort (0.21 median U-Factor), Complementary Wood Specialty Windows - Direct-Set reaches 0.14 on its lowest-conductivity package — #23 of 408 in Wood, tied with 10 others at 0.14, more insulating than 91.9% of Wood lines, top 8.1% (-0.07 vs Wood peers). Pairing NFRC ID AND across multi-pane fills shifts U-Factor from 0.32 down toward 0.14.
Mapping NFRC SHGC values (0.14 to 0.56) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 1,872 configurations meet ENERGY STAR Most Efficient criteria while 2,329 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Lifecycle documentation anchors AND to 2026-03-12 certification (FENSTAR issued 2019-01-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 84.0 BTU/hr conductive loss (-36.4% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 7,588 certified glazing combinations for Complementary Wood Specialty Windows - Direct-Set (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 2,329 packages (900 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 2,992 packages (1,468 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 3,521 packages (840 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 5,688 packages (1,080 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Weather Shield Mfg., Inc. — 630 Wood Direct Set | Wood | 0.14 | 0.13 | 5,555 |
| JELD-WEN, inc. — Siteline Clad Wood (W-5500) Fixed Direct Set Geo | Wood | 0.14 | 0.13 | 4,582 |
| Kolbe and Kolbe Millwork Co., Inc — Ultra Push-Out Casement Picture | Wood | 0.14 | 0.10 | 2,719 |
| Kolbe and Kolbe Millwork Co., Inc — Ultra Casement_Sliding Door Transom Sash Set | Wood | 0.14 | 0.09 | 1,868 |
| Sierra Pacific Windows — Clad Aspen Fixed | Wood | 0.14 | 0.10 | 1,585 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation Complementary Wood Specialty Windows - Direct-Set appear below.
What U-Factor and SHGC range does Andersen Corporation Complementary Wood Specialty Windows - Direct-Set achieve?
Across 7,588 tested NFRC glazing configurations, Andersen Corporation Complementary Wood Specialty Windows - Direct-Set with Wood framing and Fixed Window (FIXD) style reaches a 0.14 minimum U-Factor and 0.14-0.56 SHGC band. It places #72 among 1,352 Window series—top 10.0%.
Does Andersen Corporation Complementary Wood Specialty Windows - Direct-Set qualify for the ENERGY STAR Northern Zone?
Cold-climate buyers get 2,329 compliant Northern packages inside Complementary Wood Specialty Windows - Direct-Set, reaching down to U 0.14. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.
What BTU/hr heat transfer results from Complementary Wood Specialty Windows - Direct-Set's 0.14 minimum U-Factor?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Complementary Wood Specialty Windows - Direct-Set at U 0.14 conducts 84.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
What are the practical limitations of specifying Complementary Wood Specialty Windows - Direct-Set?
Skip Complementary Wood Specialty Windows - Direct-Set if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Complementary Wood Specialty Windows - Direct-Set options exceeding U 0.22.
Can you install Andersen Corporation Complementary Wood Specialty Windows - Direct-Set in Southern or South-Central zones?
Across Northern, North-Central, South-Central, Southern, 5,688 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Andersen Corporation Complementary Wood Specialty Windows - Direct-Set, while total line SHGC reaches 0.56 in colder packages.
How many Andersen Corporation Complementary Wood Specialty Windows - Direct-Set variants earn ENERGY STAR Most Efficient?
No. Exactly 1,872 of 7,588 configurations (24.7%) earn ENERGY STAR Most Efficient status in Complementary Wood Specialty Windows - Direct-Set; the remaining standard v7.0 options pass base zone limits only.
What federal compliance checks govern 2026 Complementary Wood Specialty Windows - Direct-Set window swaps?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Complementary Wood Specialty Windows - Direct-Set retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
How do you cross-check NFRC AND and product line AND-N-106 on delivery?
Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-106 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation Complementary Wood Specialty Windows - Direct-Set come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)