Andersen Corporation — 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window · Picture Window
Positioning #136/1,352 in certified Window, Andersen Corporation 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window pairs Wood frame construction with 2,446 glazing options rated between 0.13 and 0.48 SHGC across Northern, North-Central, South-Central, Southern. Across 111 certified Andersen Corporation product families, its thermal resistance spans 0.15 to 0.32 U-Factor and the line includes 452 ENERGY STAR Most Efficient packages (18.5% of line).
- Min U-Factor
- 0.15
- SHGC Range
- 0.13-0.48
- Certified Options
- 2,446
- Category Standing
- #136 of 1,352
How does Andersen Corporation 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window compare thermally against Window peers?
Andersen Corporation 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Relative to Window assemblies nationwide (median U 0.20), 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window is 0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.15-0.32.
Mapping NFRC SHGC values (0.13 to 0.48) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 452 configurations meet ENERGY STAR Most Efficient criteria while 532 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Data provenance links certification 2025-04-11 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 90.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 2,446 certified glazing combinations for 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 532 packages (150 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 1,157 packages (290 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 1,325 packages (180 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 1,887 packages (330 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Pella Corporation — Architect Wood Fixed Casement | Wood | 0.15 | 0.11 | 2,468 |
| Marvin — Elevate Direct Glaze | Wood | 0.15 | 0.13 | 2,250 |
| Windsor Windows and Doors — Pinnacle Clad Radius Direct Glaze | Wood | 0.15 | 0.13 | 1,266 |
| Kolbe and Kolbe Millwork Co., Inc — Ultra Casement Picture | Wood | 0.15 | 0.10 | 1,263 |
| Kolbe and Kolbe Millwork Co., Inc — Heritage Casement | Wood | 0.15 | 0.09 | 1,084 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window appear below.
Where does Andersen Corporation 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window stand thermally among ENERGY STAR Window lines?
Testing puts Andersen Corporation 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window at rank #136 of 1,352 Window entries with U 0.15 to 0.32 across 2,446 configurations. Solar heat gain ranges between 0.13 and 0.48 across Northern, North-Central, South-Central, Southern.
Is 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window approved for Northern Zone heating climates?
Cold-climate buyers get 532 compliant Northern packages inside 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window, reaching down to U 0.15. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.
What BTU/hr heat transfer results from 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window's 0.15 minimum U-Factor?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.15 U-Factor yields 90.0 BTU/hr conductive transfer (-31.8% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
What are the practical limitations of specifying 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.
How many 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window glazing packages pass Southern solar-heat rules?
Warm-climate homeowners have 1,887 Southern-approved options within 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window spanning SHGC down to 0.13. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
Which package tier in 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window holds Most Efficient recognition?
No. Exactly 452 of 2,446 configurations (18.5%) earn ENERGY STAR Most Efficient status in 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window; the remaining standard v7.0 options pass base zone limits only.
Can homeowners claim Form 5695 credits on Andersen Corporation 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window in 2026?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
What permanent glass etch marks verify 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window after sticker removal?
Verify NFRC ID AND and series AND-N-76 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)