Skip to main content
Window · Wood Frame NFRC AND · Product Line AND-N-105 ENERGY STAR Most Efficient Eligible

Andersen Corporation — 200 Series/400 Series Complementary Clad Specialty Windows · Picture Window

EPA ENERGY STAR Version 7.0 certifies 12,778 variants inside Andersen Corporation 200 Series/400 Series Complementary Clad Specialty Windows, combining Wood frame construction with U-Factors spanning 0.15 to 0.32 and SHGC 0.14 to 0.55. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #136 of 1,352 among 1,352 Window families and posts 0.06 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.

Min U-Factor
0.15
SHGC Range
0.14-0.55
Certified Options
12,778
Category Standing
#136 of 1,352

How does Andersen Corporation 200 Series/400 Series Complementary Clad Specialty Windows compare thermally against Window peers?

Andersen Corporation 200 Series/400 Series Complementary Clad Specialty Windows achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 200 Series/400 Series Complementary Clad Specialty WindowsHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing 200 Series/400 Series Complementary Clad Specialty Windows (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

200 Series/400 Series Complementary Clad Specialty Windows Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 200 Series/400 Series Complementary Clad Specialty Windows is 0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.15-0.32.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 1,894 configurations meet ENERGY STAR Most Efficient criteria while 2,465 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.15 U-Factor yields 90.0 BTU/hr transfer (-42.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-01-08 licensing and 2024-08-08 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 12,778 certified glazing combinations for 200 Series/400 Series Complementary Clad Specialty Windows (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 2,465 packages (808 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 5,203 packages (1,368 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 5,876 packages (768 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 10,047 packages (1,150 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Marvin — Ultimate Wood Casement Picture Wood 0.15 0.11 14,371
Neuma Door — Inswing/Outswing Sidelite Wood 0.15 0.00 8,852
Marvin — Ultimate Wood Casement Push Out Picture Wood 0.15 0.11 7,126
Pella Corporation — Architect Wood Fixed Casement Wood 0.15 0.11 2,468
Marvin — Elevate Direct Glaze Wood 0.15 0.13 2,250

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 200 Series/400 Series Complementary Clad Specialty Windows appear below.

What U-Factor and SHGC range does Andersen Corporation 200 Series/400 Series Complementary Clad Specialty Windows achieve?

Andersen Corporation 200 Series/400 Series Complementary Clad Specialty Windows spans 12,778 certified configurations with U-Factors between 0.15 and 0.32 and SHGC values from 0.14 to 0.55. Ranked #136 of 1,352 Window families, it carries 1,894 Most Efficient options.

Which glazing options in Andersen Corporation 200 Series/400 Series Complementary Clad Specialty Windows meet Northern climate limits?

Yes. 2,465 packages in Andersen Corporation 200 Series/400 Series Complementary Clad Specialty Windows clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

What BTU/hr heat transfer results from 200 Series/400 Series Complementary Clad Specialty Windows's 0.15 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 200 Series/400 Series Complementary Clad Specialty Windows at U 0.15 conducts 90.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Which situations make 200 Series/400 Series Complementary Clad Specialty Windows the wrong window or door choice?

Do not specify 200 Series/400 Series Complementary Clad Specialty Windows without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 200 Series/400 Series Complementary Clad Specialty Windows options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

What Southern ENERGY STAR v7.0 options exist in 200 Series/400 Series Complementary Clad Specialty Windows?

Yes. 10,047 Southern-certified options inside Andersen Corporation 200 Series/400 Series Complementary Clad Specialty Windows satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.55 SHGC on west-facing glass to avoid excess afternoon solar gain.

How many Andersen Corporation 200 Series/400 Series Complementary Clad Specialty Windows variants earn ENERGY STAR Most Efficient?

EPA lists 1,894 Most Efficient options (14.8% share) inside Andersen Corporation 200 Series/400 Series Complementary Clad Specialty Windows, out of 12,778 total Version 7.0 entries.

Can homeowners claim Form 5695 credits on Andersen Corporation 200 Series/400 Series Complementary Clad Specialty Windows in 2026?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Andersen Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

What permanent glass etch marks verify 200 Series/400 Series Complementary Clad Specialty Windows after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-105 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 200 Series/400 Series Complementary Clad Specialty Windows come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros