Skip to main content
Window · Wood Frame NFRC NND · Product Line NND-M-16

Neuma Door — Inswing/Outswing Sidelite · Sidelite

With a minimum U-Factor of 0.15—-0.05 compared against the 0.20 Window median—Neuma Door Inswing/Outswing Sidelite spans 8,852 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code NND, the Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.00 and 0.12.

Min U-Factor
0.15
SHGC Range
0.00-0.12
Certified Options
8,852
Category Standing
#136 of 1,352

How does Neuma Door Inswing/Outswing Sidelite compare thermally against Window peers?

Neuma Door Inswing/Outswing Sidelite achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Inswing/Outswing SideliteHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing Inswing/Outswing Sidelite (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Inswing/Outswing Sidelite Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Inswing/Outswing Sidelite spans 8,852 NFRC test records (NND), ranking #136 of 1,352 Window families (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%). Its 0.15 thermal floor compares at -0.06 against the Wood median (0.21).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 8,842 combinations qualify in the Northern Zone alongside 8,852 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Lifecycle documentation anchors NND to 2025-03-10 certification (FENSTAR issued 2018-01-23). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 90.0 BTU/hr conductive loss (-31.8% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 8,852 certified glazing combinations for Inswing/Outswing Sidelite (NFRC NND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 8,842 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 8,842 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 8,852 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 8,852 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Neuma Door produce?

Compare other active Neuma Door certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Neuma Door Inswing/Outswing Sidelite appear below.

What thermal performance numbers separate Neuma Door Inswing/Outswing Sidelite from peers?

Testing puts Neuma Door Inswing/Outswing Sidelite at rank #136 of 1,352 Window entries with U 0.15 to 0.28 across 8,852 configurations. Solar heat gain ranges between 0.00 and 0.12 across Northern, North-Central, South-Central, Southern.

Does Neuma Door Inswing/Outswing Sidelite qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern compliance covers 8,842 Inswing/Outswing Sidelite packages (U floor 0.15, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.

What conductive BTU/hr difference separates Inswing/Outswing Sidelite from the 0.22 Northern rule?

At U 0.15, a standard 3x5 ft (15 sq ft) Inswing/Outswing Sidelite opening transfers 90.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -42.0 BTU/hr difference.

What homeowner profiles are a poor match for Neuma Door Inswing/Outswing Sidelite?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Inswing/Outswing Sidelite options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

Does Inswing/Outswing Sidelite meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 8,852 Southern-approved options within Inswing/Outswing Sidelite spanning SHGC down to 0.00. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Does Inswing/Outswing Sidelite carry EPA Most Efficient certification across its lineup?

Zero glazing builds inside Inswing/Outswing Sidelite's 8,852 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

Do 2026 Inswing/Outswing Sidelite installations qualify for IRS Section 25C tax credits?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Neuma Door upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

What permanent glass etch marks verify Inswing/Outswing Sidelite after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line NND-M-16 and NFRC ID NND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Neuma Door Inswing/Outswing Sidelite come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)