Neuma Door — Inswing/Outswing Sidelite · Sidelite
With a minimum U-Factor of 0.15—-0.05 compared against the 0.20 Window median—Neuma Door Inswing/Outswing Sidelite spans 8,852 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code NND, the Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.00 and 0.12.
- Min U-Factor
- 0.15
- SHGC Range
- 0.00-0.12
- Certified Options
- 8,852
- Category Standing
- #136 of 1,352
How does Neuma Door Inswing/Outswing Sidelite compare thermally against Window peers?
Neuma Door Inswing/Outswing Sidelite achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across Inswing/Outswing Sidelite spans 8,852 NFRC test records (NND), ranking #136 of 1,352 Window families (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%). Its 0.15 thermal floor compares at -0.06 against the Wood median (0.21).
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 8,842 combinations qualify in the Northern Zone alongside 8,852 Southern configurations matching hot-climate SHGC <= 0.23 caps.
Lifecycle documentation anchors NND to 2025-03-10 certification (FENSTAR issued 2018-01-23). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 90.0 BTU/hr conductive loss (-31.8% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 8,852 certified glazing combinations for Inswing/Outswing Sidelite (NFRC NND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 8,842 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 8,842 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 8,852 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 8,852 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Marvin — Ultimate Wood Casement Push Out Picture | Wood | 0.15 | 0.11 | 7,126 |
| Andersen Corporation — 200 Series/400 Series Complementary Clad Specialty Windows | Wood | 0.15 | 0.14 | 12,778 |
| Marvin — Ultimate Wood Casement Picture | Wood | 0.15 | 0.11 | 14,371 |
| Pella Corporation — Architect Wood Fixed Casement | Wood | 0.15 | 0.11 | 2,468 |
| Andersen Corporation — 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window | Wood | 0.15 | 0.13 | 2,446 |
What other certified series does Neuma Door produce?
Compare other active Neuma Door certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Inswing/Outswing Hinged Entry Door
U-Factor 0.14–0.28 · 7,646 certified options.
Neuma Hinged Door
U-Factor 0.16–0.28 · 195 certified options.
Excel Hinged Door
U-Factor 0.24–0.28 · 186 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Neuma Door Inswing/Outswing Sidelite appear below.
What thermal performance numbers separate Neuma Door Inswing/Outswing Sidelite from peers?
Testing puts Neuma Door Inswing/Outswing Sidelite at rank #136 of 1,352 Window entries with U 0.15 to 0.28 across 8,852 configurations. Solar heat gain ranges between 0.00 and 0.12 across Northern, North-Central, South-Central, Southern.
Does Neuma Door Inswing/Outswing Sidelite qualify for the ENERGY STAR Northern Zone?
Prescriptive Northern compliance covers 8,842 Inswing/Outswing Sidelite packages (U floor 0.15, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.
What conductive BTU/hr difference separates Inswing/Outswing Sidelite from the 0.22 Northern rule?
At U 0.15, a standard 3x5 ft (15 sq ft) Inswing/Outswing Sidelite opening transfers 90.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -42.0 BTU/hr difference.
What homeowner profiles are a poor match for Neuma Door Inswing/Outswing Sidelite?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Inswing/Outswing Sidelite options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.
Does Inswing/Outswing Sidelite meet Southern hot-climate SHGC caps (<= 0.23)?
Warm-climate homeowners have 8,852 Southern-approved options within Inswing/Outswing Sidelite spanning SHGC down to 0.00. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
Does Inswing/Outswing Sidelite carry EPA Most Efficient certification across its lineup?
Zero glazing builds inside Inswing/Outswing Sidelite's 8,852 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.
Do 2026 Inswing/Outswing Sidelite installations qualify for IRS Section 25C tax credits?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Neuma Door upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
What permanent glass etch marks verify Inswing/Outswing Sidelite after sticker removal?
Confirm both the paper NFRC label and permanent corner glass etch match line NND-M-16 and NFRC ID NND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Neuma Door Inswing/Outswing Sidelite come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)