Skip to main content
Door · Other Frame NFRC NND · Product Line NND-M-14

Neuma Door — Excel Hinged Door · Swinging Entry Door (Single)

Positioning #199/268 in certified Door, Neuma Door Excel Hinged Door pairs Other frame construction with 186 glazing options rated between 0.03 and 0.21 SHGC across Northern, North-Central, South-Central, Southern. Across 10 certified Neuma Door product families, its thermal resistance spans 0.24 to 0.28 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.24
SHGC Range
0.03-0.21
Certified Options
186
Category Standing
#199 of 268

How does Neuma Door Excel Hinged Door compare thermally against Door peers?

Neuma Door Excel Hinged Door achieves a 0.24 thermal floor across Door lines, placing #199 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Excel Hinged DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Excel Hinged Door (U 0.24).28<=0.15650.16-0.18510.19-0.21710.22-0.24This model: U 0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Excel Hinged Door Cohort StandingMin U-Factor 0.24 stands at rank #199 of 268, outperforming 19.8% of peers.Min U-Factor 0.24Rank #199 of 268 (19.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 10 certified Neuma Door series, this Swinging Entry Door, Single offers a 0.04 U-Factor adjustment span between 0.28 entry options and 0.24 top-performing glazing. Category standing is #199/268 (tied with 16 others at 0.24, more insulating than 19.8% of Door lines).

Mapping NFRC SHGC values (0.03 to 0.21) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 104 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Registry history records EPA FENSTAR licensing on 2018-01-23 and v7.0 data certification on 2025-03-10. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.24 conducts 144.0 BTU/hr (+12.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 186 certified glazing combinations for Excel Hinged Door (NFRC NND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 104 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 104 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 186 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 186 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Neuma Door produce?

Compare other active Neuma Door certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Neuma Door Excel Hinged Door appear below.

What thermal performance numbers separate Neuma Door Excel Hinged Door from peers?

Built with Other framing in Entry Door Single-Lite (EDSL) style, Neuma Door Excel Hinged Door offers 186 Version 7.0 configurations from U 0.24 up to 0.28, posting +0.03 against the Door median of 0.21 with 0 Most Efficient picks.

Which glazing options in Neuma Door Excel Hinged Door meet Northern climate limits?

Prescriptive Northern approval ends at U <= 0.22, above Excel Hinged Door's 0.24 minimum. However, 104 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

How do you calculate winter heat conduction for Neuma Door Excel Hinged Door?

Using NFRC NND U-Factor 0.24, a 15 sq ft Entry Door Single-Lite (EDSL) assembly conducts 144.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+12.0 BTU/hr margin).

Who should NOT choose Neuma Door Excel Hinged Door for a residential project?

Do not specify Excel Hinged Door without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Excel Hinged Door options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Can you install Neuma Door Excel Hinged Door in Southern or South-Central zones?

Exactly 186 Excel Hinged Door options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.03 rather than higher 0.21 glass.

What glazing share inside Excel Hinged Door qualifies as Most Efficient?

All 186 Excel Hinged Door listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

What 2026 federal tax credit and Lead RRP rules apply to Excel Hinged Door?

Any Excel Hinged Door purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

Where are NFRC and IGCC identification marks located on Excel Hinged Door?

Verify NFRC ID NND and series NND-M-14 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Neuma Door Excel Hinged Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros