Neuma Door — Inswing/Outswing Hinged Entry Door · Swinging Entry Door (Single)
Positioning #11/268 in certified Door, Neuma Door Inswing/Outswing Hinged Entry Door pairs Wood frame with Fiberglass sash with 7,646 glazing options rated between 0.00 and 0.34 SHGC across Northern, North-Central, South-Central, Southern. Across 10 certified Neuma Door product families, its thermal resistance spans 0.14 to 0.28 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.
- Min U-Factor
- 0.14
- SHGC Range
- 0.00-0.34
- Certified Options
- 7,646
- Category Standing
- #11 of 268
How does Neuma Door Inswing/Outswing Hinged Entry Door compare thermally against Door peers?
Neuma Door Inswing/Outswing Hinged Entry Door achieves a 0.14 thermal floor across Door lines, placing #11 of 268 against the 0.21 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 10 certified Neuma Door series, this Swinging Entry Door, Single offers a 0.14 U-Factor adjustment span between 0.28 entry options and 0.14 top-performing glazing. Category standing is #11/268 (tied with 6 others at 0.14, more insulating than 93.7% of Door lines, top 6.3%).
Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 7,432 combinations qualify in the Northern Zone alongside 7,019 Southern configurations matching hot-climate SHGC <= 0.23 caps.
Registry history records EPA FENSTAR licensing on 2018-01-23 and v7.0 data certification on 2025-03-10. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.14 conducts 84.0 BTU/hr (-48.0 BTU/hr vs the 0.22 ceiling).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 7,646 certified glazing combinations for Inswing/Outswing Hinged Entry Door (NFRC NND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 7,432 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 7,432 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 7,019 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 7,019 packages (0 Most Eff.) |
Which competing Door series sit closest on U-Factor?
Inspect nearby Door competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Masonite International Corporation — Fiberglass LXF Door | Wood | 0.14 | 0.01 | 260 |
| Kolbe and Kolbe Millwork Co., Inc — Forgent Sliding Door | Vinyl / Wood | 0.14 | 0.09 | 779 |
| Alpen HPP, LLC dba Alpen High Performance Products — Zenith Grandline Sliding Glass Door | Fiberglass | 0.14 | 0.11 | 217 |
| Alpen HPP, LLC dba Alpen High Performance Products — Zenith Narrowline Sliding Glass Door | Fiberglass | 0.14 | 0.12 | 179 |
| Vytex Corporation — 8200 Sliding Glass Door | Vinyl | 0.14 | 0.13 | 52 |
What other certified series does Neuma Door produce?
Compare other active Neuma Door certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Neuma Hinged Door
U-Factor 0.16–0.28 · 195 certified options.
Excel Hinged Door
U-Factor 0.24–0.28 · 186 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Neuma Door Inswing/Outswing Hinged Entry Door appear below.
How efficient is Neuma Door Inswing/Outswing Hinged Entry Door compared with peer Door models?
Built with Wood framing in Entry Door Single-Lite (EDSL) style, Neuma Door Inswing/Outswing Hinged Entry Door offers 7,646 Version 7.0 configurations from U 0.14 up to 0.28, posting -0.07 against the Door median of 0.21 with 0 Most Efficient picks.
Is Inswing/Outswing Hinged Entry Door approved for Northern Zone heating climates?
Neuma Door Inswing/Outswing Hinged Entry Door supplies 7,432 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.28, so inspect the NFRC order sheet before purchase.
How does a 3x5 ft Inswing/Outswing Hinged Entry Door window perform under a 40 deg F temperature drop?
At U 0.14, a standard 3x5 ft (15 sq ft) Inswing/Outswing Hinged Entry Door opening transfers 84.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -48.0 BTU/hr difference.
What homeowner profiles are a poor match for Neuma Door Inswing/Outswing Hinged Entry Door?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Inswing/Outswing Hinged Entry Door options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
How many Inswing/Outswing Hinged Entry Door glazing packages pass Southern solar-heat rules?
Yes, Inswing/Outswing Hinged Entry Door holds 7,019 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.00 SHGC in cooling climates.
Are all 7,646 Inswing/Outswing Hinged Entry Door configurations ENERGY STAR Most Efficient?
No. Zero of the 7,646 configurations in Neuma Door Inswing/Outswing Hinged Entry Door hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.
What 2026 federal tax credit and Lead RRP rules apply to Inswing/Outswing Hinged Entry Door?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Neuma Door upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
How do building inspectors verify Inswing/Outswing Hinged Entry Door glass specs on job sites?
Inspectors match the temporary NFRC sticker (U 0.14-0.28, SHGC 0.00-0.34) against permit drawings for line NND-M-8. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Neuma Door Inswing/Outswing Hinged Entry Door come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)