Skip to main content
Door · Wood Frame NFRC STN · Product Line STN-K-37

Masonite International Corporation — Fiberglass LXF Door · Swinging Entry Door (Single)

Positioning #11/268 in certified Door, Masonite International Corporation Fiberglass LXF Door pairs Wood frame construction with 260 glazing options rated between 0.01 and 0.23 SHGC across Northern, North-Central, South-Central, Southern. Across 13 certified Masonite International Corporation product families, its thermal resistance spans 0.14 to 0.28 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.14
SHGC Range
0.01-0.23
Certified Options
260
Category Standing
#11 of 268

How does Masonite International Corporation Fiberglass LXF Door compare thermally against Door peers?

Masonite International Corporation Fiberglass LXF Door achieves a 0.14 thermal floor across Door lines, placing #11 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Fiberglass LXF DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin <=0.15 containing Fiberglass LXF Door (U 0.14).28<=0.15This model: U 0.14650.16-0.18510.19-0.21710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Fiberglass LXF Door Cohort StandingMin U-Factor 0.14 stands at rank #11 of 268, outperforming 93.7% of peers.Min U-Factor 0.14Rank #11 of 268 (93.7% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Wood cohort (0.21 median U-Factor), Fiberglass LXF Door reaches 0.14 on its lowest-conductivity package — #23 of 408 in Wood, tied with 10 others at 0.14, more insulating than 91.9% of Wood lines, top 8.1% (-0.07 vs Wood peers). Pairing NFRC ID STN across multi-pane fills shifts U-Factor from 0.28 down toward 0.14.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 182 combinations qualify in the Northern Zone alongside 260 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.14 U-Factor yields 84.0 BTU/hr transfer (-48.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2025-03-25 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 260 certified glazing combinations for Fiberglass LXF Door (NFRC STN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 182 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 182 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 260 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 260 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Masonite International Corporation produce?

Compare other active Masonite International Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Masonite International Corporation Fiberglass LXF Door appear below.

How efficient is Masonite International Corporation Fiberglass LXF Door compared with peer Door models?

Testing puts Masonite International Corporation Fiberglass LXF Door at rank #11 of 268 Door entries with U 0.14 to 0.28 across 260 configurations. Solar heat gain ranges between 0.01 and 0.23 across Northern, North-Central, South-Central, Southern.

Can homeowners install Fiberglass LXF Door in cold Northern ENERGY STAR counties?

Yes. 182 packages in Masonite International Corporation Fiberglass LXF Door clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.28.

How much winter heat loss does Fiberglass LXF Door conduct across a 15 sq ft opening?

At U 0.14, a standard 3x5 ft (15 sq ft) Fiberglass LXF Door opening transfers 84.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -48.0 BTU/hr difference.

When should a buyer skip Masonite International Corporation Fiberglass LXF Door and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Fiberglass LXF Door options exceeding U 0.22. Additionally, do not order Entry Door Single-Lite (EDSL) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

What Southern ENERGY STAR v7.0 options exist in Fiberglass LXF Door?

Exactly 260 Fiberglass LXF Door options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.01 rather than higher 0.23 glass.

Which package tier in Fiberglass LXF Door holds Most Efficient recognition?

Zero glazing builds inside Fiberglass LXF Door's 260 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

What federal compliance checks govern 2026 Fiberglass LXF Door window swaps?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Fiberglass LXF Door installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do you cross-check NFRC STN and product line STN-K-37 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code STN and product line STN-K-37, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Masonite International Corporation Fiberglass LXF Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros