Skip to main content
Window · Wood Frame NFRC STN · Product Line STN-M-24

Masonite International Corporation — Masonite Fiberglass Skin Sidelite · Sidelite

Across 13 Masonite International Corporation certified families, Masonite Fiberglass Skin Sidelite supplies 321,052 Sidelite configurations starting at 0.15 U-Factor and 0.01 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.19 SHGC. Its thermal floor ranks #136 of 1,352 category entries—0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.15
SHGC Range
0.01-0.19
Certified Options
321,052
Category Standing
#136 of 1,352

How does Masonite International Corporation Masonite Fiberglass Skin Sidelite compare thermally against Window peers?

Masonite International Corporation Masonite Fiberglass Skin Sidelite achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Masonite Fiberglass Skin SideliteHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing Masonite Fiberglass Skin Sidelite (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Masonite Fiberglass Skin Sidelite Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Masonite Fiberglass Skin Sidelite spans 321,052 NFRC test records (STN), ranking #136 of 1,352 Window families (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%). Its 0.15 thermal floor compares at -0.06 against the Wood median (0.21).

Regional qualification covers Northern, North-Central, South-Central, Southern. 302,557 combinations qualify in the Northern Zone alongside 321,052 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.15 U-Factor yields 90.0 BTU/hr transfer (-42.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-02-29 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 321,052 certified glazing combinations for Masonite Fiberglass Skin Sidelite (NFRC STN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 302,557 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 302,557 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 321,052 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 321,052 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Masonite International Corporation produce?

Compare other active Masonite International Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Masonite International Corporation Masonite Fiberglass Skin Sidelite appear below.

How well does Masonite Fiberglass Skin Sidelite by Masonite International Corporation insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 321,052 configurations for Masonite International Corporation Masonite Fiberglass Skin Sidelite covering Northern, North-Central, South-Central, Southern, dropping down to U 0.15 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Does Masonite International Corporation Masonite Fiberglass Skin Sidelite qualify for the ENERGY STAR Northern Zone?

Yes. 302,557 packages in Masonite International Corporation Masonite Fiberglass Skin Sidelite clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.28.

What BTU/hr heat transfer results from Masonite Fiberglass Skin Sidelite's 0.15 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.15 U-Factor yields 90.0 BTU/hr conductive transfer (-31.8% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What homeowner profiles are a poor match for Masonite International Corporation Masonite Fiberglass Skin Sidelite?

Do not specify Masonite Fiberglass Skin Sidelite without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Masonite Fiberglass Skin Sidelite options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

How many Masonite Fiberglass Skin Sidelite glazing packages pass Southern solar-heat rules?

Yes, Masonite Fiberglass Skin Sidelite holds 321,052 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.01 SHGC in cooling climates.

Which package tier in Masonite Fiberglass Skin Sidelite holds Most Efficient recognition?

All 321,052 Masonite Fiberglass Skin Sidelite listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

Do 2026 Masonite Fiberglass Skin Sidelite installations qualify for IRS Section 25C tax credits?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Masonite Fiberglass Skin Sidelite retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do you cross-check NFRC STN and product line STN-M-24 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code STN and product line STN-M-24, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Masonite International Corporation Masonite Fiberglass Skin Sidelite come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)