Masonite International Corporation — Masonite Steel Wood Edge Steel Door · Swinging Entry Door (Single)
Masonite International Corporation engineered the Masonite Steel Wood Edge Steel Door Swinging Entry Door, Single line for Northern, North-Central, South-Central, Southern, certifying 77,544 glass-spacer combinations from 0.13 to 0.28 U-Factor and 0.01 to 0.33 SHGC. Relative to other Wood models tracked under NFRC STN, its minimum U-Factor is 0.08 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.13
- SHGC Range
- 0.01-0.33
- Certified Options
- 77,544
- Category Standing
- #6 of 268
How does Masonite International Corporation Masonite Steel Wood Edge Steel Door compare thermally against Door peers?
Masonite International Corporation Masonite Steel Wood Edge Steel Door achieves a 0.13 thermal floor across Door lines, placing #6 of 268 against the 0.21 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Masonite International Corporation Masonite Steel Wood Edge Steel Door standing at #6 of 268 certified Door product series, tied with 4 others at 0.13, more insulating than 96.3% of Door lines, top 3.7%. Comparing Wood profiles alone (median 0.21) shows -0.08 before selecting Low-E tiers.
Climate coverage for Masonite International Corporation Masonite Steel Wood Edge Steel Door spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 70,467 combinations qualify in the Northern Zone alongside 75,793 Southern configurations matching hot-climate SHGC <= 0.23 caps.
Lifecycle documentation anchors STN to 2024-02-29 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 78.0 BTU/hr conductive loss (-40.9% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 77,544 certified glazing combinations for Masonite Steel Wood Edge Steel Door (NFRC STN) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 70,467 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 70,467 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 75,793 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 75,793 packages (0 Most Eff.) |
Which competing Door series sit closest on U-Factor?
Inspect nearby Door competitors clustered closest to 0.13 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Kohltech International, Ltd. — Steel Door | Wood | 0.13 | 0.01 | 77,762 |
| Pella Corporation — Pella Entry Doors - Wood Edge Steel Door | Wood | 0.13 | 0.01 | 76,045 |
| Specialty Wholesale Supply — Wood Edge Steel Entry/Patio Door | Wood | 0.13 | 0.01 | 76,045 |
| Masonite International Corporation — Masonite Steel Wood Edge Steel Door | Wood | 0.13 | 0.01 | 77,538 |
| Neuma Door — Inswing/Outswing Hinged Entry Door | Wood | 0.14 | 0.00 | 7,646 |
What other certified series does Masonite International Corporation produce?
Compare other active Masonite International Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Masonite Steel Wood Edge Steel Door
U-Factor 0.13–0.28 · 77,538 certified options.
Fiberglass LXF Door
U-Factor 0.14–0.28 · 260 certified options.
Masonite Fiberglass Skin Door
U-Factor 0.15–0.28 · 244,260 certified options.
Masonite Fiberglass Skin Door
U-Factor 0.15–0.28 · 244,193 certified options.
Masonite Fiberglass Skin Sidelite
U-Factor 0.15–0.28 · 321,052 certified options.
Masonite Fiberglass Skin Sidelite
U-Factor 0.15–0.28 · 321,052 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Masonite International Corporation Masonite Steel Wood Edge Steel Door appear below.
How well does Masonite Steel Wood Edge Steel Door by Masonite International Corporation insulate relative to Door benchmarks?
Masonite International Corporation Masonite Steel Wood Edge Steel Door spans 77,544 certified configurations with U-Factors between 0.13 and 0.28 and SHGC values from 0.01 to 0.33. Ranked #6 of 268 Door families, it carries 0 Most Efficient options.
Can homeowners install Masonite Steel Wood Edge Steel Door in cold Northern ENERGY STAR counties?
Prescriptive Northern compliance covers 70,467 Masonite Steel Wood Edge Steel Door packages (U floor 0.13, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.
How does a 3x5 ft Masonite Steel Wood Edge Steel Door window perform under a 40 deg F temperature drop?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 78.0 BTU/hr on Masonite Steel Wood Edge Steel Door's lowest-U package (0.13), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.28 transfer proportionally more energy.
What homeowner profiles are a poor match for Masonite International Corporation Masonite Steel Wood Edge Steel Door?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Masonite Steel Wood Edge Steel Door options exceeding U 0.22. Additionally, do not order Entry Door Single-Lite (EDSL) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
How many Masonite Steel Wood Edge Steel Door glazing packages pass Southern solar-heat rules?
Warm-climate homeowners have 75,793 Southern-approved options within Masonite Steel Wood Edge Steel Door spanning SHGC down to 0.01. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
Are all 77,544 Masonite Steel Wood Edge Steel Door configurations ENERGY STAR Most Efficient?
All 77,544 Masonite Steel Wood Edge Steel Door listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.
How do the 25C sunset and pre-1978 Lead RRP rules affect Masonite Steel Wood Edge Steel Door?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
Where are NFRC and IGCC identification marks located on Masonite Steel Wood Edge Steel Door?
Confirm both the paper NFRC label and permanent corner glass etch match line STN-K-27 and NFRC ID STN before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Masonite International Corporation Masonite Steel Wood Edge Steel Door come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)