Skip to main content
Door · Wood Frame NFRC MAK · Product Line MAK-K-42

Specialty Wholesale Supply — Wood Edge Steel Entry/Patio Door · Swinging Entry Door (Single)

With a minimum U-Factor of 0.13—-0.08 compared against the 0.21 Door median—Specialty Wholesale Supply Wood Edge Steel Entry/Patio Door spans 76,045 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code MAK, the Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.01 and 0.32.

Min U-Factor
0.13
SHGC Range
0.01-0.32
Certified Options
76,045
Category Standing
#6 of 268

How does Specialty Wholesale Supply Wood Edge Steel Entry/Patio Door compare thermally against Door peers?

Specialty Wholesale Supply Wood Edge Steel Entry/Patio Door achieves a 0.13 thermal floor across Door lines, placing #6 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Wood Edge Steel Entry/Patio DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin <=0.15 containing Wood Edge Steel Entry/Patio Door (U 0.13).28<=0.15This model: U 0.13650.16-0.18510.19-0.21710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Wood Edge Steel Entry/Patio Door Cohort StandingMin U-Factor 0.13 stands at rank #6 of 268, outperforming 96.3% of peers.Min U-Factor 0.13Rank #6 of 268 (96.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Wood Edge Steel Entry/Patio Door spans 76,045 NFRC test records (MAK), ranking #6 of 268 Door families (tied with 4 others at 0.13, more insulating than 96.3% of Door lines, top 3.7%). Its 0.13 thermal floor compares at -0.08 against the Wood median (0.21).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 69,021 combinations qualify in the Northern Zone alongside 74,467 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.13 U-Factor yields 78.0 BTU/hr transfer (-54.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-02-20 licensing and 2025-04-23 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 76,045 certified glazing combinations for Wood Edge Steel Entry/Patio Door (NFRC MAK) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 69,021 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 69,021 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 74,467 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 74,467 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.13 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Specialty Wholesale Supply produce?

Compare other active Specialty Wholesale Supply certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Specialty Wholesale Supply Wood Edge Steel Entry/Patio Door appear below.

What thermal performance numbers separate Specialty Wholesale Supply Wood Edge Steel Entry/Patio Door from peers?

Across 76,045 tested NFRC glazing configurations, Specialty Wholesale Supply Wood Edge Steel Entry/Patio Door with Wood framing and Entry Door Single-Lite (EDSL) style reaches a 0.13 minimum U-Factor and 0.01-0.32 SHGC band. It places #6 among 268 Door series—top 3.7%.

Which glazing options in Specialty Wholesale Supply Wood Edge Steel Entry/Patio Door meet Northern climate limits?

Prescriptive Northern compliance covers 69,021 Wood Edge Steel Entry/Patio Door packages (U floor 0.13, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.

How does a 3x5 ft Wood Edge Steel Entry/Patio Door window perform under a 40 deg F temperature drop?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 78.0 BTU/hr on Wood Edge Steel Entry/Patio Door's lowest-U package (0.13), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.28 transfer proportionally more energy.

What are the practical limitations of specifying Wood Edge Steel Entry/Patio Door?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Wood Edge Steel Entry/Patio Door options exceeding U 0.22. Additionally, do not order Entry Door Single-Lite (EDSL) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Can you install Specialty Wholesale Supply Wood Edge Steel Entry/Patio Door in Southern or South-Central zones?

Yes, Wood Edge Steel Entry/Patio Door holds 74,467 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.01 SHGC in cooling climates.

Are all 76,045 Wood Edge Steel Entry/Patio Door configurations ENERGY STAR Most Efficient?

No. Zero of the 76,045 configurations in Specialty Wholesale Supply Wood Edge Steel Entry/Patio Door hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

How do the 25C sunset and pre-1978 Lead RRP rules affect Wood Edge Steel Entry/Patio Door?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Wood Edge Steel Entry/Patio Door installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How can homeowners confirm delivered Specialty Wholesale Supply Wood Edge Steel Entry/Patio Door units match permits?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code MAK and product line MAK-K-42, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Specialty Wholesale Supply Wood Edge Steel Entry/Patio Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros