Skip to main content
Window · Vinyl Frame NFRC MAK · Product Line MAK-K-33 ENERGY STAR Most Efficient Eligible

Specialty Wholesale Supply — 7100/7600 TrustGard Awning · Awning (Projected)

EPA ENERGY STAR Version 7.0 certifies 361 variants inside Specialty Wholesale Supply 7100/7600 TrustGard Awning, combining Vinyl frame construction with U-Factors spanning 0.19 to 0.29 and SHGC 0.17 to 0.43. Qualifying for Northern, North-Central, South-Central, Southern, this Awning, Projected family places #564 of 1,352 among 1,352 Window families and posts matches the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.19
SHGC Range
0.17-0.43
Certified Options
361
Category Standing
#564 of 1,352

How does Specialty Wholesale Supply 7100/7600 TrustGard Awning compare thermally against Window peers?

Specialty Wholesale Supply 7100/7600 TrustGard Awning achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 7100/7600 TrustGard AwningHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing 7100/7600 TrustGard Awning (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

7100/7600 TrustGard Awning Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), 7100/7600 TrustGard Awning reaches 0.19 on its lowest-conductivity package — #429 of 1,009 in Vinyl, tied with 83 others at 0.19, more insulating than 49.3% of Vinyl lines (At median vs Vinyl peers). Pairing NFRC ID MAK across multi-pane fills shifts U-Factor from 0.29 down toward 0.19.

Regional qualification covers Northern, North-Central, South-Central, Southern. 96 configurations meet ENERGY STAR Most Efficient criteria while 142 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-02-20 and v7.0 data certification on 2025-09-04. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.19 conducts 114.0 BTU/hr (-18.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 361 certified glazing combinations for 7100/7600 TrustGard Awning (NFRC MAK) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 142 packages (16 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 272 packages (47 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 286 packages (47 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 290 packages (96 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Specialty Wholesale Supply produce?

Compare other active Specialty Wholesale Supply certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Specialty Wholesale Supply 7100/7600 TrustGard Awning appear below.

How well does 7100/7600 TrustGard Awning by Specialty Wholesale Supply insulate relative to Window benchmarks?

Specialty Wholesale Supply 7100/7600 TrustGard Awning spans 361 certified configurations with U-Factors between 0.19 and 0.29 and SHGC values from 0.17 to 0.43. Ranked #564 of 1,352 Window families, it carries 96 Most Efficient options.

Is 7100/7600 TrustGard Awning approved for Northern Zone heating climates?

Specialty Wholesale Supply 7100/7600 TrustGard Awning supplies 142 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.29, so inspect the NFRC order sheet before purchase.

What BTU/hr heat transfer results from 7100/7600 TrustGard Awning's 0.19 minimum U-Factor?

Using NFRC MAK U-Factor 0.19, a 15 sq ft Projected Awning (PRAW) assembly conducts 114.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-18.0 BTU/hr margin).

When should a buyer skip Specialty Wholesale Supply 7100/7600 TrustGard Awning and compare alternatives?

Skip 7100/7600 TrustGard Awning if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 7100/7600 TrustGard Awning options exceeding U 0.22.

Can you install Specialty Wholesale Supply 7100/7600 TrustGard Awning in Southern or South-Central zones?

Across Northern, North-Central, South-Central, Southern, 290 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Specialty Wholesale Supply 7100/7600 TrustGard Awning, while total line SHGC reaches 0.43 in colder packages.

Which package tier in 7100/7600 TrustGard Awning holds Most Efficient recognition?

EPA lists 96 Most Efficient options (26.6% share) inside Specialty Wholesale Supply 7100/7600 TrustGard Awning, out of 361 total Version 7.0 entries.

Do 2026 7100/7600 TrustGard Awning installations qualify for IRS Section 25C tax credits?

Any 7100/7600 TrustGard Awning purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

Where are NFRC and IGCC identification marks located on 7100/7600 TrustGard Awning?

Match the NFRC thermal sticker for code MAK and line MAK-K-33 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Specialty Wholesale Supply 7100/7600 TrustGard Awning come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros