Skip to main content
Door · Steel / Wood Frame NFRC MAK · Product Line MAK-K-44

Specialty Wholesale Supply — Metal Edge/Steel Entry Door · Swinging Entry Door (Single)

EPA ENERGY STAR Version 7.0 certifies 64,485 variants inside Specialty Wholesale Supply Metal Edge/Steel Entry Door, combining Steel / Wood frame construction with U-Factors spanning 0.16 to 0.28 and SHGC 0.01 to 0.29. Qualifying for Northern, North-Central, South-Central, Southern, this Swinging Entry Door, Single family places #29 of 268 among 268 Door families and posts matches the 0.16 Btu/hr·ft²·°F median among Steel / Wood peers.

Min U-Factor
0.16
SHGC Range
0.01-0.29
Certified Options
64,485
Category Standing
#29 of 268

How does Specialty Wholesale Supply Metal Edge/Steel Entry Door compare thermally against Door peers?

Specialty Wholesale Supply Metal Edge/Steel Entry Door achieves a 0.16 thermal floor across Door lines, placing #29 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Metal Edge/Steel Entry DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Metal Edge/Steel Entry Door (U 0.16).28<=0.15650.16-0.18This model: U 0.16510.19-0.21710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Metal Edge/Steel Entry Door Cohort StandingMin U-Factor 0.16 stands at rank #29 of 268, outperforming 79.9% of peers.Min U-Factor 0.16Rank #29 of 268 (79.9% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Door assemblies nationwide (median U 0.21), Metal Edge/Steel Entry Door is 0.05 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median while keeping Steel / Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.16-0.28.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 50,235 combinations qualify in the Northern Zone alongside 64,250 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.16 U-Factor yields 96.0 BTU/hr transfer (-36.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-02-20 licensing and 2025-09-18 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 64,485 certified glazing combinations for Metal Edge/Steel Entry Door (NFRC MAK) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 50,235 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 50,235 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 64,250 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 64,250 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Specialty Wholesale Supply produce?

Compare other active Specialty Wholesale Supply certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Specialty Wholesale Supply Metal Edge/Steel Entry Door appear below.

What U-Factor and SHGC range does Specialty Wholesale Supply Metal Edge/Steel Entry Door achieve?

Specialty Wholesale Supply Metal Edge/Steel Entry Door spans 64,485 certified configurations with U-Factors between 0.16 and 0.28 and SHGC values from 0.01 to 0.29. Ranked #29 of 268 Door families, it carries 0 Most Efficient options.

Can homeowners install Metal Edge/Steel Entry Door in cold Northern ENERGY STAR counties?

Cold-climate buyers get 50,235 compliant Northern packages inside Metal Edge/Steel Entry Door, reaching down to U 0.16. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.28 options.

How does a 3x5 ft Metal Edge/Steel Entry Door window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.16 U-Factor yields 96.0 BTU/hr conductive transfer (-27.3% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What are the practical limitations of specifying Metal Edge/Steel Entry Door?

Do not specify Metal Edge/Steel Entry Door without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Metal Edge/Steel Entry Door options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Is Metal Edge/Steel Entry Door suitable for sunbelt cooling-dominated homes?

Yes. 64,250 Southern-certified options inside Specialty Wholesale Supply Metal Edge/Steel Entry Door satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.29 SHGC on west-facing glass to avoid excess afternoon solar gain.

Does Metal Edge/Steel Entry Door carry EPA Most Efficient certification across its lineup?

ENERGY STAR Most Efficient designation is absent across all 64,485 Metal Edge/Steel Entry Door options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

How do the 25C sunset and pre-1978 Lead RRP rules affect Metal Edge/Steel Entry Door?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Metal Edge/Steel Entry Door installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How can homeowners confirm delivered Specialty Wholesale Supply Metal Edge/Steel Entry Door units match permits?

Match the NFRC thermal sticker for code MAK and line MAK-K-44 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Specialty Wholesale Supply Metal Edge/Steel Entry Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros