Masonite International Corporation — Masonite Steel Steel Edge Steel Door · Swinging Entry Door (Single)
Across 13 Masonite International Corporation certified families, Masonite Steel Steel Edge Steel Door supplies 64,485 Swinging Entry Door, Single configurations starting at 0.16 U-Factor and 0.01 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.29 SHGC. Its thermal floor ranks #29 of 268 category entries—0.05 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.16
- SHGC Range
- 0.01-0.29
- Certified Options
- 64,485
- Category Standing
- #29 of 268
How does Masonite International Corporation Masonite Steel Steel Edge Steel Door compare thermally against Door peers?
Masonite International Corporation Masonite Steel Steel Edge Steel Door achieves a 0.16 thermal floor across Door lines, placing #29 of 268 against the 0.21 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Steel / Wood cohort (0.16 median U-Factor), Masonite Steel Steel Edge Steel Door reaches 0.16 on its lowest-conductivity package — #1 of 4 in Steel / Wood, tied with 2 others at 0.16, more insulating than 25.0% of Steel / Wood lines (At median vs Steel / Wood peers). Pairing NFRC ID STN across multi-pane fills shifts U-Factor from 0.28 down toward 0.16.
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 50,235 combinations qualify in the Northern Zone alongside 64,250 Southern configurations matching hot-climate SHGC <= 0.23 caps.
Lifecycle documentation anchors STN to 2024-02-29 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 96.0 BTU/hr conductive loss (-27.3% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 64,485 certified glazing combinations for Masonite Steel Steel Edge Steel Door (NFRC STN) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 50,235 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 50,235 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 64,250 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 64,250 packages (0 Most Eff.) |
Which competing Door series sit closest on U-Factor?
Inspect nearby Door competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Specialty Wholesale Supply — Metal Edge/Steel Entry Door | Steel / Wood | 0.16 | 0.01 | 64,485 |
| Marvin — Ultimate Sliding Glass Door G2 | Wood | 0.16 | 0.09 | 31,210 |
| Quaker Window Products — V300 Inswing Door | Vinyl | 0.16 | 0.08 | 17,041 |
| Quaker Window Products — V300/V600 Outswing Door | Vinyl | 0.16 | 0.08 | 16,974 |
| Wincore Window Company, LLC — Fiberglass Entry Door | Composite / Steel / Wood | 0.16 | 0.00 | 11,717 |
What other certified series does Masonite International Corporation produce?
Compare other active Masonite International Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Masonite Steel Wood Edge Steel Door
U-Factor 0.13–0.28 · 77,538 certified options.
Masonite Steel Wood Edge Steel Door
U-Factor 0.13–0.28 · 77,544 certified options.
Fiberglass LXF Door
U-Factor 0.14–0.28 · 260 certified options.
Masonite Fiberglass Skin Door
U-Factor 0.15–0.28 · 244,260 certified options.
Masonite Fiberglass Skin Door
U-Factor 0.15–0.28 · 244,193 certified options.
Masonite Fiberglass Skin Sidelite
U-Factor 0.15–0.28 · 321,052 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Masonite International Corporation Masonite Steel Steel Edge Steel Door appear below.
How well does Masonite Steel Steel Edge Steel Door by Masonite International Corporation insulate relative to Door benchmarks?
Masonite International Corporation Masonite Steel Steel Edge Steel Door spans 64,485 certified configurations with U-Factors between 0.16 and 0.28 and SHGC values from 0.01 to 0.29. Ranked #29 of 268 Door families, it carries 0 Most Efficient options.
Does Masonite International Corporation Masonite Steel Steel Edge Steel Door qualify for the ENERGY STAR Northern Zone?
Prescriptive Northern compliance covers 50,235 Masonite Steel Steel Edge Steel Door packages (U floor 0.16, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.
What BTU/hr heat transfer results from Masonite Steel Steel Edge Steel Door's 0.16 minimum U-Factor?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.16 U-Factor yields 96.0 BTU/hr conductive transfer (-27.3% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
What are the practical limitations of specifying Masonite Steel Steel Edge Steel Door?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Masonite Steel Steel Edge Steel Door options exceeding U 0.22. Additionally, do not order Entry Door Single-Lite (EDSL) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Can you install Masonite International Corporation Masonite Steel Steel Edge Steel Door in Southern or South-Central zones?
Yes. 64,250 Southern-certified options inside Masonite International Corporation Masonite Steel Steel Edge Steel Door satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.29 SHGC on west-facing glass to avoid excess afternoon solar gain.
How many Masonite International Corporation Masonite Steel Steel Edge Steel Door variants earn ENERGY STAR Most Efficient?
No. Zero of the 64,485 configurations in Masonite International Corporation Masonite Steel Steel Edge Steel Door hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.
How do the 25C sunset and pre-1978 Lead RRP rules affect Masonite Steel Steel Edge Steel Door?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Masonite Steel Steel Edge Steel Door installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
Where are NFRC and IGCC identification marks located on Masonite Steel Steel Edge Steel Door?
Confirm both the paper NFRC label and permanent corner glass etch match line STN-M-22 and NFRC ID STN before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Masonite International Corporation Masonite Steel Steel Edge Steel Door come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)