Skip to main content
Window · Vinyl Frame NFRC MAK · Product Line MAK-K-32 ENERGY STAR Most Efficient Eligible

Specialty Wholesale Supply — 7000/7500 TrustGard Casement · Casement Windows

Specialty Wholesale Supply 7000/7500 TrustGard Casement is a Casement Windows assembly with a Vinyl frame that reaches a minimum U-Factor of 0.19 across 327 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #564 of 1,352 in Window, its thermal floor is 0.01 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.07 to 0.43.

Min U-Factor
0.19
SHGC Range
0.07-0.43
Certified Options
327
Category Standing
#564 of 1,352

How does Specialty Wholesale Supply 7000/7500 TrustGard Casement compare thermally against Window peers?

Specialty Wholesale Supply 7000/7500 TrustGard Casement achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 7000/7500 TrustGard CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing 7000/7500 TrustGard Casement (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

7000/7500 TrustGard Casement Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 7000/7500 TrustGard Casement spans 327 NFRC test records (MAK), ranking #564 of 1,352 Window families (tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%). Its 0.19 thermal floor compares at At median against the Vinyl median (0.19).

Climate coverage for Specialty Wholesale Supply 7000/7500 TrustGard Casement spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 101 configurations meet ENERGY STAR Most Efficient criteria while 150 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-02-20 and v7.0 data certification on 2024-12-16. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.19 conducts 114.0 BTU/hr (-18.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 327 certified glazing combinations for 7000/7500 TrustGard Casement (NFRC MAK) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 150 packages (13 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 251 packages (44 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 257 packages (44 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 264 packages (101 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Northeast Windows USA, Inc. — CW390 Casement Vinyl 0.19 0.08 325
Northeast Windows USA, Inc. — PW4015 Vinyl 0.19 0.10 295
WeatherBarr Windows and Doors — 9520 Picture Window Vinyl 0.19 0.18 364
Northeast Windows USA, Inc. — AW390 Awning Vinyl 0.19 0.08 285
Value Windows & Doors — Onyx Casement Vinyl 0.19 0.08 281

What other certified series does Specialty Wholesale Supply produce?

Compare other active Specialty Wholesale Supply certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Specialty Wholesale Supply 7000/7500 TrustGard Casement appear below.

How well does 7000/7500 TrustGard Casement by Specialty Wholesale Supply insulate relative to Window benchmarks?

Specialty Wholesale Supply 7000/7500 TrustGard Casement spans 327 certified configurations with U-Factors between 0.19 and 0.32 and SHGC values from 0.07 to 0.43. Ranked #564 of 1,352 Window families, it carries 101 Most Efficient options.

Is 7000/7500 TrustGard Casement approved for Northern Zone heating climates?

Specialty Wholesale Supply 7000/7500 TrustGard Casement supplies 150 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

How do you calculate winter heat conduction for Specialty Wholesale Supply 7000/7500 TrustGard Casement?

At U 0.19, a standard 3x5 ft (15 sq ft) 7000/7500 TrustGard Casement opening transfers 114.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -18.0 BTU/hr difference.

When should a buyer skip Specialty Wholesale Supply 7000/7500 TrustGard Casement and compare alternatives?

Skip 7000/7500 TrustGard Casement if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 7000/7500 TrustGard Casement options exceeding U 0.22.

What Southern ENERGY STAR v7.0 options exist in 7000/7500 TrustGard Casement?

Warm-climate homeowners have 264 Southern-approved options within 7000/7500 TrustGard Casement spanning SHGC down to 0.07. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Does 7000/7500 TrustGard Casement carry EPA Most Efficient certification across its lineup?

Not every package qualifies: 101 of 327 7000/7500 TrustGard Casement glazing builds earn Most Efficient recognition (30.9%), while other variants sit on the standard Version 7.0 tier.

What federal compliance checks govern 2026 7000/7500 TrustGard Casement window swaps?

Any 7000/7500 TrustGard Casement purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do building inspectors verify 7000/7500 TrustGard Casement glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line MAK-K-32 and NFRC ID MAK before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Specialty Wholesale Supply 7000/7500 TrustGard Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)