Skip to main content
Window · Vinyl Frame NFRC VWS · Product Line VWS-A-70 ENERGY STAR Most Efficient Eligible

Value Windows & Doors — Onyx Casement · Casement Windows

Value Windows & Doors engineered the Onyx Casement Casement Windows line for North-Central, South-Central, Southern, certifying 281 glass-spacer combinations from 0.19 to 0.31 U-Factor and 0.08 to 0.19 SHGC. Relative to other Vinyl models tracked under NFRC VWS, its minimum U-Factor is matches the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.19
SHGC Range
0.08-0.19
Certified Options
281
Category Standing
#564 of 1,352

How does Value Windows & Doors Onyx Casement compare thermally against Window peers?

Value Windows & Doors Onyx Casement achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Onyx CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Onyx Casement (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Onyx Casement Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Value Windows & Doors Onyx Casement standing at #564 of 1,352 certified Window product series, tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%. Comparing Vinyl profiles alone (median 0.19) shows At median before selecting Low-E tiers.

Regional qualification covers North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.08 lowers cooling load.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.19 U-Factor yields 114.0 BTU/hr transfer (-18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-01-31 licensing and 2026-11-04 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 281 certified glazing combinations for Onyx Casement (NFRC VWS) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 74 packages (22 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 270 packages (22 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 281 packages (50 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Northeast Windows USA, Inc. — AW390 Awning Vinyl 0.19 0.08 285
Northeast Windows USA, Inc. — PW4015 Vinyl 0.19 0.10 295
Advanced Window Corp. — 6300 Sliding Window Vinyl 0.19 0.17 256
Joyce Manufacturing Co. — Insulator INCA Casement Vinyl 0.19 0.14 243
Joyce Manufacturing Co. — Insulator INAW Awning Vinyl 0.19 0.14 242

What other certified series does Value Windows & Doors produce?

Compare other active Value Windows & Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Value Windows & Doors Onyx Casement appear below.

Where does Value Windows & Doors Onyx Casement stand thermally among ENERGY STAR Window lines?

Built with Vinyl framing in Casement Single-Vent (CSSV) style, Value Windows & Doors Onyx Casement offers 281 Version 7.0 configurations from U 0.19 up to 0.31, posting -0.01 against the Window median of 0.20 with 50 Most Efficient picks.

Which glazing options in Value Windows & Doors Onyx Casement meet Northern climate limits?

This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.19). Focus on North-Central, South-Central, Southern glazing applications where SHGC 0.08-0.19 manages cooling loads.

How much winter heat loss does Onyx Casement conduct across a 15 sq ft opening?

Using NFRC VWS U-Factor 0.19, a 15 sq ft Casement Single-Vent (CSSV) assembly conducts 114.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-18.0 BTU/hr margin).

When should a buyer skip Value Windows & Doors Onyx Casement and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Onyx Casement options exceeding U 0.22. Additionally, do not order Casement Single-Vent (CSSV) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Can you install Value Windows & Doors Onyx Casement in Southern or South-Central zones?

Across North-Central, South-Central, Southern, 281 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Value Windows & Doors Onyx Casement, while total line SHGC reaches 0.19 in colder packages.

Are all 281 Onyx Casement configurations ENERGY STAR Most Efficient?

No. Exactly 50 of 281 configurations (17.8%) earn ENERGY STAR Most Efficient status in Onyx Casement; the remaining standard v7.0 options pass base zone limits only.

What 2026 federal tax credit and Lead RRP rules apply to Onyx Casement?

Any Onyx Casement purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do you cross-check NFRC VWS and product line VWS-A-70 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line VWS-A-70 and NFRC ID VWS before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Value Windows & Doors Onyx Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros