Advanced Window Corp. — 6300 Sliding Window · Double Slider
Across 16 Advanced Window Corp. certified families, 6300 Sliding Window supplies 256 Double Slider configurations starting at 0.19 U-Factor and 0.17 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.45 SHGC. Its thermal floor ranks #564 of 1,352 category entries—0.01 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.19
- SHGC Range
- 0.17-0.45
- Certified Options
- 256
- Category Standing
- #564 of 1,352
How does Advanced Window Corp. 6300 Sliding Window compare thermally against Window peers?
Advanced Window Corp. 6300 Sliding Window achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Advanced Window Corp. 6300 Sliding Window standing at #564 of 1,352 certified Window product series, tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%. Comparing Vinyl profiles alone (median 0.19) shows At median before selecting Low-E tiers.
Mapping NFRC SHGC values (0.17 to 0.45) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 38 configurations meet ENERGY STAR Most Efficient criteria while 88 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.19 U-Factor yields 114.0 BTU/hr transfer (-18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-06-13 licensing and 2026-04-29 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 256 certified glazing combinations for 6300 Sliding Window (NFRC ADC) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 88 packages (18 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 160 packages (26 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 192 packages (20 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 192 packages (32 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Joyce Manufacturing Co. — Insulator INCA Casement | Vinyl | 0.19 | 0.14 | 243 |
| Joyce Manufacturing Co. — Insulator INAW Awning | Vinyl | 0.19 | 0.14 | 242 |
| Value Windows & Doors — Onyx Casement | Vinyl | 0.19 | 0.08 | 281 |
| Northeast Windows USA, Inc. — AW390 Awning | Vinyl | 0.19 | 0.08 | 285 |
| Northeast Windows USA, Inc. — PW4015 | Vinyl | 0.19 | 0.10 | 295 |
What other certified series does Advanced Window Corp. produce?
Compare other active Advanced Window Corp. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
EU 76 Septem Tilt Turn
U-Factor 0.14–0.26 · 324 certified options.
EU 76 Septem Balcony Door
U-Factor 0.15–0.25 · 360 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Advanced Window Corp. 6300 Sliding Window appear below.
How efficient is Advanced Window Corp. 6300 Sliding Window compared with peer Window models?
Testing puts Advanced Window Corp. 6300 Sliding Window at rank #564 of 1,352 Window entries with U 0.19 to 0.28 across 256 configurations. Solar heat gain ranges between 0.17 and 0.45 across Northern, North-Central, South-Central, Southern.
Can homeowners install 6300 Sliding Window in cold Northern ENERGY STAR counties?
Cold-climate buyers get 88 compliant Northern packages inside 6300 Sliding Window, reaching down to U 0.19. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.28 options.
How much winter heat loss does 6300 Sliding Window conduct across a 15 sq ft opening?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.19 U-Factor yields 114.0 BTU/hr conductive transfer (-13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
Who should NOT choose Advanced Window Corp. 6300 Sliding Window for a residential project?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 6300 Sliding Window options exceeding U 0.22. Additionally, do not order Dual-Slide Horizontal (HSXX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Is 6300 Sliding Window suitable for sunbelt cooling-dominated homes?
Exactly 192 6300 Sliding Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.17 rather than higher 0.45 glass.
Does 6300 Sliding Window carry EPA Most Efficient certification across its lineup?
Within 6300 Sliding Window, 14.8% (38 of 256) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.
What 2026 federal tax credit and Lead RRP rules apply to 6300 Sliding Window?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
How can homeowners confirm delivered Advanced Window Corp. 6300 Sliding Window units match permits?
Confirm both the paper NFRC label and permanent corner glass etch match line ADC-K-20 and NFRC ID ADC before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Advanced Window Corp. 6300 Sliding Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)