Window · Vinyl Frame NFRC NEW · Product Line NEW-A-22 ENERGY STAR Most Efficient Eligible

Northeast Windows USA, Inc. — PW4015 · Picture Window

Across 10 Northeast Windows USA, Inc. certified families, PW4015 supplies 295 Picture Window configurations starting at 0.19 U-Factor and 0.10 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.56 SHGC. Its thermal floor ranks #564 of 1,352 category entries—0.01 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.19
SHGC Range
0.10-0.56
Certified Options
295
Category Standing
#564 of 1,352

How does Northeast Windows USA, Inc. PW4015 compare thermally against Window peers?

Northeast Windows USA, Inc. PW4015 achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. PW4015Histogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing PW4015 (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

PW4015 Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Northeast Windows USA, Inc. PW4015 at rank #564 of 1,352 (tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.10-0.56 band.

Regional qualification covers Northern, North-Central, South-Central, Southern. 38 configurations meet ENERGY STAR Most Efficient criteria while 160 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 114.0 BTU/hr (-13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-10-03 and cert timestamp 2024-11-17.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 295 certified glazing combinations for PW4015 (NFRC NEW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 160 packages (11 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 201 packages (11 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 86 packages (1 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 91 packages (28 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Value Windows & Doors — Onyx Casement Vinyl 0.19 0.08 281
Specialty Wholesale Supply — 7000/7500 TrustGard Casement Vinyl 0.19 0.07 327
Advanced Window Corp. — 6300 Sliding Window Vinyl 0.19 0.17 256
Joyce Manufacturing Co. — Insulator INCA Casement Vinyl 0.19 0.14 243
Joyce Manufacturing Co. — Insulator INAW Awning Vinyl 0.19 0.14 242

What other certified series does Northeast Windows USA, Inc. produce?

Compare other active Northeast Windows USA, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Northeast Windows USA, Inc. PW4015 appear below.

How efficient is Northeast Windows USA, Inc. PW4015 compared with peer Window models?

Across 295 tested NFRC glazing configurations, Northeast Windows USA, Inc. PW4015 with Vinyl framing and Fixed Window (FIXD) style reaches a 0.19 minimum U-Factor and 0.10-0.56 SHGC band. It places #564 among 1,352 Window series—top 49.6%.

Is PW4015 approved for Northern Zone heating climates?

Cold-climate buyers get 160 compliant Northern packages inside PW4015, reaching down to U 0.19. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

How do you calculate winter heat conduction for Northeast Windows USA, Inc. PW4015?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.19 U-Factor yields 114.0 BTU/hr conductive transfer (-13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

When should a buyer skip Northeast Windows USA, Inc. PW4015 and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on PW4015 options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

What Southern ENERGY STAR v7.0 options exist in PW4015?

Yes. 91 Southern-certified options inside Northeast Windows USA, Inc. PW4015 satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.56 SHGC on west-facing glass to avoid excess afternoon solar gain.

Does PW4015 carry EPA Most Efficient certification across its lineup?

Not every package qualifies: 38 of 295 PW4015 glazing builds earn Most Efficient recognition (12.9%), while other variants sit on the standard Version 7.0 tier.

Can homeowners claim Form 5695 credits on Northeast Windows USA, Inc. PW4015 in 2026?

Any PW4015 purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

Where are NFRC and IGCC identification marks located on PW4015?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code NEW and product line NEW-A-22, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Northeast Windows USA, Inc. PW4015 come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)