Skip to main content
Window · Vinyl Frame NFRC NEW · Product Line NEW-A-24 ENERGY STAR Most Efficient Eligible

Northeast Windows USA, Inc. — CW300 Casement · Casement Windows

Northeast Windows USA, Inc. CW300 Casement is a Casement Windows assembly with a Vinyl frame that reaches a minimum U-Factor of 0.21 across 266 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #742 of 1,352 in Window, its thermal floor is 0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.08 to 0.43.

Min U-Factor
0.21
SHGC Range
0.08-0.43
Certified Options
266
Category Standing
#742 of 1,352

How does Northeast Windows USA, Inc. CW300 Casement compare thermally against Window peers?

Northeast Windows USA, Inc. CW300 Casement achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. CW300 CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing CW300 Casement (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

CW300 Casement Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), CW300 Casement is 0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.21-0.32.

Mapping NFRC SHGC values (0.08 to 0.43) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 34 configurations meet ENERGY STAR Most Efficient criteria while 64 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors NEW to 2024-03-15 certification (FENSTAR issued 2018-10-03). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 126.0 BTU/hr conductive loss (-4.5% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 266 certified glazing combinations for CW300 Casement (NFRC NEW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 64 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 159 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 210 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 215 packages (34 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Northeast Windows USA, Inc. produce?

Compare other active Northeast Windows USA, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Northeast Windows USA, Inc. CW300 Casement appear below.

How efficient is Northeast Windows USA, Inc. CW300 Casement compared with peer Window models?

Testing puts Northeast Windows USA, Inc. CW300 Casement at rank #742 of 1,352 Window entries with U 0.21 to 0.32 across 266 configurations. Solar heat gain ranges between 0.08 and 0.43 across Northern, North-Central, South-Central, Southern.

Can homeowners install CW300 Casement in cold Northern ENERGY STAR counties?

Yes. 64 packages in Northeast Windows USA, Inc. CW300 Casement clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

What conductive BTU/hr difference separates CW300 Casement from the 0.22 Northern rule?

Using NFRC NEW U-Factor 0.21, a 15 sq ft Casement Single-Vent (CSSV) assembly conducts 126.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-6.0 BTU/hr margin).

Which situations make CW300 Casement the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on CW300 Casement options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Is CW300 Casement suitable for sunbelt cooling-dominated homes?

Exactly 215 CW300 Casement options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.08 rather than higher 0.43 glass.

Which package tier in CW300 Casement holds Most Efficient recognition?

Within CW300 Casement, 12.8% (34 of 266) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

What federal compliance checks govern 2026 CW300 Casement window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current CW300 Casement retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do building inspectors verify CW300 Casement glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.21-0.32, SHGC 0.08-0.43) against permit drawings for line NEW-A-24. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Northeast Windows USA, Inc. CW300 Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)