Gerkin Windows and Doors — 6500 Fixed Window · Picture Window
Gerkin Windows and Doors engineered the 6500 Fixed Window Picture Window line for Northern, North-Central, South-Central, Southern, certifying 266 glass-spacer combinations from 0.21 to 0.32 U-Factor and 0.10 to 0.51 SHGC. Relative to other Vinyl models tracked under NFRC GER, its minimum U-Factor is 0.02 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.21
- SHGC Range
- 0.10-0.51
- Certified Options
- 266
- Category Standing
- #742 of 1,352
How does Gerkin Windows and Doors 6500 Fixed Window compare thermally against Window peers?
Gerkin Windows and Doors 6500 Fixed Window achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across 6500 Fixed Window spans 266 NFRC test records (GER), ranking #742 of 1,352 Window families (tied with 88 others at 0.21, more insulating than 38.6% of Window lines). Its 0.21 thermal floor compares at +0.02 against the Vinyl median (0.19).
Regional qualification covers Northern, North-Central, South-Central, Southern. 14 configurations meet ENERGY STAR Most Efficient criteria while 41 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Lifecycle documentation anchors GER to 2026-09-04 certification (FENSTAR issued 2018-08-23). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 126.0 BTU/hr conductive loss (-4.5% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 266 certified glazing combinations for 6500 Fixed Window (NFRC GER) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 41 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 112 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 118 packages (0 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 199 packages (14 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Northeast Windows USA, Inc. — CW300 Casement | Vinyl | 0.21 | 0.08 | 266 |
| Earthwise Group, LLC — 140.148 / 143.191 / 143.148 Casement | Vinyl | 0.21 | 0.12 | 280 |
| WeatherBarr Windows and Doors — 5000 Replacement Casement Picture Window | Vinyl | 0.21 | 0.16 | 244 |
| Earthwise Group, LLC — 140.148 / 143.191 / 143.148 Awning | Vinyl | 0.21 | 0.12 | 289 |
| Northeast Windows USA, Inc. — AW300 Awning | Vinyl | 0.21 | 0.08 | 240 |
What other certified series does Gerkin Windows and Doors produce?
Compare other active Gerkin Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Gerkin Windows and Doors 6500 Fixed Window appear below.
Where does Gerkin Windows and Doors 6500 Fixed Window stand thermally among ENERGY STAR Window lines?
Testing puts Gerkin Windows and Doors 6500 Fixed Window at rank #742 of 1,352 Window entries with U 0.21 to 0.32 across 266 configurations. Solar heat gain ranges between 0.10 and 0.51 across Northern, North-Central, South-Central, Southern.
Is 6500 Fixed Window approved for Northern Zone heating climates?
Gerkin Windows and Doors 6500 Fixed Window supplies 41 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.
How much winter heat loss does 6500 Fixed Window conduct across a 15 sq ft opening?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 126.0 BTU/hr on 6500 Fixed Window's lowest-U package (0.21), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.
What homeowner profiles are a poor match for Gerkin Windows and Doors 6500 Fixed Window?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 6500 Fixed Window options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Is 6500 Fixed Window suitable for sunbelt cooling-dominated homes?
Warm-climate homeowners have 199 Southern-approved options within 6500 Fixed Window spanning SHGC down to 0.10. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
Which package tier in 6500 Fixed Window holds Most Efficient recognition?
Within 6500 Fixed Window, 5.3% (14 of 266) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.
What federal compliance checks govern 2026 6500 Fixed Window window swaps?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Gerkin Windows and Doors upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
How do building inspectors verify 6500 Fixed Window glass specs on job sites?
Inspectors match the temporary NFRC sticker (U 0.21-0.32, SHGC 0.10-0.51) against permit drawings for line GER-K-10. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Gerkin Windows and Doors 6500 Fixed Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)