Skip to main content
Window · Vinyl Frame NFRC GER · Product Line GER-K-8

Gerkin Windows and Doors — 6100 Single Hung · Single Hung

Gerkin Windows and Doors engineered the 6100 Single Hung Single Hung line for South-Central, Southern, certifying 91 glass-spacer combinations from 0.26 to 0.32 U-Factor and 0.14 to 0.23 SHGC. Relative to other Vinyl models tracked under NFRC GER, its minimum U-Factor is 0.07 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.26
SHGC Range
0.14-0.23
Certified Options
91
Category Standing
#1,256 of 1,352

How does Gerkin Windows and Doors 6100 Single Hung compare thermally against Window peers?

Gerkin Windows and Doors 6100 Single Hung achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 6100 Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing 6100 Single Hung (U 0.26).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.26310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

6100 Single Hung Cohort StandingMin U-Factor 0.26 stands at rank #1,256 of 1,352, outperforming 4.5% of peers.Min U-Factor 0.26Rank #1,256 of 1,352 (4.5% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Gerkin Windows and Doors 6100 Single Hung at rank #1,256 of 1,352 (tied with 35 others at 0.26, more insulating than 4.5% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.14-0.23 band.

Mapping NFRC SHGC values (0.14 to 0.23) against ENERGY STAR Version 7.0 targets approves South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.14 lowers cooling load.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.26 U-Factor yields 156.0 BTU/hr transfer (+24.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-08-23 licensing and 2024-02-03 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 91 certified glazing combinations for 6100 Single Hung (NFRC GER) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 27 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 91 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Gerkin Windows and Doors produce?

Compare other active Gerkin Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Gerkin Windows and Doors 6100 Single Hung appear below.

How efficient is Gerkin Windows and Doors 6100 Single Hung compared with peer Window models?

Built with Vinyl framing in Single-Hung (VSSH) style, Gerkin Windows and Doors 6100 Single Hung offers 91 Version 7.0 configurations from U 0.26 up to 0.32, posting +0.06 against the Window median of 0.20 with 0 Most Efficient picks.

Which glazing options in Gerkin Windows and Doors 6100 Single Hung meet Northern climate limits?

No. Because 6100 Single Hung reaches only 0.26 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Vinyl line strictly across South-Central, Southern cooling or mixed markets.

How much winter heat loss does 6100 Single Hung conduct across a 15 sq ft opening?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 156.0 BTU/hr on 6100 Single Hung's lowest-U package (0.26), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

When should a buyer skip Gerkin Windows and Doors 6100 Single Hung and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 6100 Single Hung options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

What Southern ENERGY STAR v7.0 options exist in 6100 Single Hung?

Warm-climate homeowners have 91 Southern-approved options within 6100 Single Hung spanning SHGC down to 0.14. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Does 6100 Single Hung carry EPA Most Efficient certification across its lineup?

Zero glazing builds inside 6100 Single Hung's 91 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

Can homeowners claim Form 5695 credits on Gerkin Windows and Doors 6100 Single Hung in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

What permanent glass etch marks verify 6100 Single Hung after sticker removal?

Match the NFRC thermal sticker for code GER and line GER-K-8 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Gerkin Windows and Doors 6100 Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros