Skip to main content
Window · Vinyl Frame NFRC CWS · Product Line CWS-K-26

Custom Window Systems, Inc. — 615/6150 Fixed · Picture Window

EPA ENERGY STAR Version 7.0 certifies 144 variants inside Custom Window Systems, Inc. 615/6150 Fixed, combining Vinyl frame construction with U-Factors spanning 0.26 to 0.32 and SHGC 0.14 to 0.23. Qualifying for South-Central, Southern, this Picture Window family places #1,256 of 1,352 among 1,352 Window families and posts 0.07 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.26
SHGC Range
0.14-0.23
Certified Options
144
Category Standing
#1,256 of 1,352

How does Custom Window Systems, Inc. 615/6150 Fixed compare thermally against Window peers?

Custom Window Systems, Inc. 615/6150 Fixed achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 615/6150 FixedHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing 615/6150 Fixed (U 0.26).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.26310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

615/6150 Fixed Cohort StandingMin U-Factor 0.26 stands at rank #1,256 of 1,352, outperforming 4.5% of peers.Min U-Factor 0.26Rank #1,256 of 1,352 (4.5% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Custom Window Systems, Inc. 615/6150 Fixed at rank #1,256 of 1,352 (tied with 35 others at 0.26, more insulating than 4.5% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.14-0.23 band.

Climate coverage for Custom Window Systems, Inc. 615/6150 Fixed spans South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.14 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 156.0 BTU/hr (+18.2% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-09-05 and cert timestamp 2025-07-31.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 144 certified glazing combinations for 615/6150 Fixed (NFRC CWS) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 72 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 144 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Custom Window Systems, Inc. produce?

Compare other active Custom Window Systems, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Custom Window Systems, Inc. 615/6150 Fixed appear below.

How well does 615/6150 Fixed by Custom Window Systems, Inc. insulate relative to Window benchmarks?

Testing puts Custom Window Systems, Inc. 615/6150 Fixed at rank #1,256 of 1,352 Window entries with U 0.26 to 0.32 across 144 configurations. Solar heat gain ranges between 0.14 and 0.23 across South-Central, Southern.

Can homeowners install 615/6150 Fixed in cold Northern ENERGY STAR counties?

Northern Zone certification is absent for 615/6150 Fixed (0 qualifying options, min U 0.26). Install this Fixed Window (FIXD) product only within South-Central, Southern regions where lower SHGC caps apply.

How does a 3x5 ft 615/6150 Fixed window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.26 U-Factor yields 156.0 BTU/hr conductive transfer (+18.2% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What are the practical limitations of specifying 615/6150 Fixed?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 615/6150 Fixed options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Is 615/6150 Fixed suitable for sunbelt cooling-dominated homes?

Yes, 615/6150 Fixed holds 144 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.14 SHGC in cooling climates.

Which package tier in 615/6150 Fixed holds Most Efficient recognition?

All 144 615/6150 Fixed listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

Do 2026 615/6150 Fixed installations qualify for IRS Section 25C tax credits?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Custom Window Systems, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

Where are NFRC and IGCC identification marks located on 615/6150 Fixed?

Confirm both the paper NFRC label and permanent corner glass etch match line CWS-K-26 and NFRC ID CWS before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Custom Window Systems, Inc. 615/6150 Fixed come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros