Skip to main content
Window · Vinyl Frame NFRC CWS · Product Line CWS-K-8

Custom Window Systems, Inc. — C-8400 Casement · Casement Windows

Custom Window Systems, Inc. C-8400 Casement is a Casement Windows assembly with a Vinyl frame that reaches a minimum U-Factor of 0.27 across 195 certified glazing configurations covering South-Central, Southern. Ranked #1,292 of 1,352 in Window, its thermal floor is 0.07 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.11 to 0.22.

Min U-Factor
0.27
SHGC Range
0.11-0.22
Certified Options
195
Category Standing
#1,292 of 1,352

How does Custom Window Systems, Inc. C-8400 Casement compare thermally against Window peers?

Custom Window Systems, Inc. C-8400 Casement achieves a 0.27 thermal floor across Window lines, placing #1,292 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. C-8400 CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing C-8400 Casement (U 0.27).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

C-8400 Casement Cohort StandingMin U-Factor 0.27 stands at rank #1,292 of 1,352, outperforming 2.4% of peers.Min U-Factor 0.27Rank #1,292 of 1,352 (2.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 7 certified Custom Window Systems, Inc. series, this Casement Windows offers a 0.05 U-Factor adjustment span between 0.32 entry options and 0.27 top-performing glazing. Category standing is #1,292/1,352 (tied with 27 others at 0.27, more insulating than 2.4% of Window lines).

Zone eligibility across EPA boundaries reaches 2 markets (South-Central, Southern). Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.11 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 162.0 BTU/hr (+22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-09-05 and cert timestamp 2025-08-11.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 195 certified glazing combinations for C-8400 Casement (NFRC CWS) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 90 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 195 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.27 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
ViWinTech Window — Casement Vinyl 0.27 0.16 204
Comfort View Products, LLC — 1900 Vinyl Single Hung Vinyl 0.27 0.20 21
Silver Line Building Products — 2130 IMPACT Fixed Window Vinyl 0.27 0.19 20
Vytex Corporation — Georgetown Double Hung Vinyl 0.27 0.19 16
Vytex Corporation — Georgetown Horizontal Slider Vinyl 0.27 0.18 16

What other certified series does Custom Window Systems, Inc. produce?

Compare other active Custom Window Systems, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Custom Window Systems, Inc. C-8400 Casement appear below.

Where does Custom Window Systems, Inc. C-8400 Casement stand thermally among ENERGY STAR Window lines?

Custom Window Systems, Inc. C-8400 Casement spans 195 certified configurations with U-Factors between 0.27 and 0.32 and SHGC values from 0.11 to 0.22. Ranked #1,292 of 1,352 Window families, it carries 0 Most Efficient options.

Is C-8400 Casement approved for Northern Zone heating climates?

Custom Window Systems, Inc. C-8400 Casement holds zero Northern Zone qualifications (min U 0.27). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

What BTU/hr heat transfer results from C-8400 Casement's 0.27 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), C-8400 Casement at U 0.27 conducts 162.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What homeowner profiles are a poor match for Custom Window Systems, Inc. C-8400 Casement?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on C-8400 Casement options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Can you install Custom Window Systems, Inc. C-8400 Casement in Southern or South-Central zones?

Yes. 195 Southern-certified options inside Custom Window Systems, Inc. C-8400 Casement satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.22 SHGC on west-facing glass to avoid excess afternoon solar gain.

How many Custom Window Systems, Inc. C-8400 Casement variants earn ENERGY STAR Most Efficient?

No. Zero of the 195 configurations in Custom Window Systems, Inc. C-8400 Casement hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

What federal compliance checks govern 2026 C-8400 Casement window swaps?

Any C-8400 Casement purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do building inspectors verify C-8400 Casement glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line CWS-K-8 and NFRC ID CWS before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Custom Window Systems, Inc. C-8400 Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros