Skip to main content
Window · Vinyl Frame NFRC VNL · Product Line VNL-M-42

ViWinTech Window — Casement · Casement Windows

ViWinTech Window Casement is a Casement Windows assembly with a Vinyl frame that reaches a minimum U-Factor of 0.27 across 204 certified glazing configurations covering South-Central, Southern. Ranked #1,292 of 1,352 in Window, its thermal floor is 0.07 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.16 to 0.23.

Min U-Factor
0.27
SHGC Range
0.16-0.23
Certified Options
204
Category Standing
#1,292 of 1,352

How does ViWinTech Window Casement compare thermally against Window peers?

ViWinTech Window Casement achieves a 0.27 thermal floor across Window lines, placing #1,292 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Casement (U 0.27).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Casement Cohort StandingMin U-Factor 0.27 stands at rank #1,292 of 1,352, outperforming 2.4% of peers.Min U-Factor 0.27Rank #1,292 of 1,352 (2.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows ViWinTech Window Casement standing at #1,292 of 1,352 certified Window product series, tied with 27 others at 0.27, more insulating than 2.4% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.08 before selecting Low-E tiers.

Regional qualification covers South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.16 lowers cooling load.

Data provenance links certification 2026-01-30 and FENSTAR license 2018-08-23 inside EPA Version 7.0 tables. Heat transfer computes to 162.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 204 certified glazing combinations for Casement (NFRC VNL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 101 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 204 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.27 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does ViWinTech Window produce?

Compare other active ViWinTech Window certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to ViWinTech Window Casement appear below.

How efficient is ViWinTech Window Casement compared with peer Window models?

Across 204 tested NFRC glazing configurations, ViWinTech Window Casement with Vinyl framing and Casement Single-Vent (CSSV) style reaches a 0.27 minimum U-Factor and 0.16-0.23 SHGC band. It places #1,292 among 1,352 Window series—more insulating than 2.4%.

How does ViWinTech Window Casement satisfy Version 7.0 Northern criteria?

No—with 0 Northern packages and a 0.27 thermal floor, ViWinTech Window Casement targets warmer South-Central, Southern climates instead of cold Northern installations.

How do you calculate winter heat conduction for ViWinTech Window Casement?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.27 U-Factor yields 162.0 BTU/hr conductive transfer (+22.7% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Which situations make Casement the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Casement options exceeding U 0.22. Additionally, do not order Casement Single-Vent (CSSV) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

How many Casement glazing packages pass Southern solar-heat rules?

Warm-climate homeowners have 204 Southern-approved options within Casement spanning SHGC down to 0.16. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Which package tier in Casement holds Most Efficient recognition?

Zero glazing builds inside Casement's 204 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

Do 2026 Casement installations qualify for IRS Section 25C tax credits?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Casement retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How can homeowners confirm delivered ViWinTech Window Casement units match permits?

Match the NFRC thermal sticker for code VNL and line VNL-M-42 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for ViWinTech Window Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros