Skip to main content
Window · Vinyl Frame NFRC CWS · Product Line CWS-K-23

Custom Window Systems, Inc. — PW-8150 Fixed · Picture Window

Custom Window Systems, Inc. PW-8150 Fixed is a Picture Window assembly with a Vinyl frame that reaches a minimum U-Factor of 0.25 across 212 certified glazing configurations covering North-Central, South-Central, Southern. Ranked #1,174 of 1,352 in Window, its thermal floor is 0.05 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.14 to 0.31.

Min U-Factor
0.25
SHGC Range
0.14-0.31
Certified Options
212
Category Standing
#1,174 of 1,352

How does Custom Window Systems, Inc. PW-8150 Fixed compare thermally against Window peers?

Custom Window Systems, Inc. PW-8150 Fixed achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. PW-8150 FixedHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing PW-8150 Fixed (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

PW-8150 Fixed Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Custom Window Systems, Inc. PW-8150 Fixed standing at #1,174 of 1,352 certified Window product series, tied with 81 others at 0.25, more insulating than 7.2% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.06 before selecting Low-E tiers.

Evaluating climate compliance across North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.14 lowers cooling load.

Registry history records EPA FENSTAR licensing on 2018-09-05 and v7.0 data certification on 2026-04-30. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.25 conducts 150.0 BTU/hr (+18.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 212 certified glazing combinations for PW-8150 Fixed (NFRC CWS) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 19 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 113 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 210 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Custom Window Systems, Inc. produce?

Compare other active Custom Window Systems, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Custom Window Systems, Inc. PW-8150 Fixed appear below.

How efficient is Custom Window Systems, Inc. PW-8150 Fixed compared with peer Window models?

Custom Window Systems, Inc. PW-8150 Fixed spans 212 certified configurations with U-Factors between 0.25 and 0.32 and SHGC values from 0.14 to 0.31. Ranked #1,174 of 1,352 Window families, it carries 0 Most Efficient options.

Which glazing options in Custom Window Systems, Inc. PW-8150 Fixed meet Northern climate limits?

No—with 0 Northern packages and a 0.25 thermal floor, Custom Window Systems, Inc. PW-8150 Fixed targets warmer North-Central, South-Central, Southern climates instead of cold Northern installations.

How do you calculate winter heat conduction for Custom Window Systems, Inc. PW-8150 Fixed?

At U 0.25, a standard 3x5 ft (15 sq ft) PW-8150 Fixed opening transfers 150.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +18.0 BTU/hr difference.

What are the practical limitations of specifying PW-8150 Fixed?

Skip PW-8150 Fixed if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on PW-8150 Fixed options exceeding U 0.22.

How many PW-8150 Fixed glazing packages pass Southern solar-heat rules?

Yes. 210 Southern-certified options inside Custom Window Systems, Inc. PW-8150 Fixed satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.31 SHGC on west-facing glass to avoid excess afternoon solar gain.

How many Custom Window Systems, Inc. PW-8150 Fixed variants earn ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 212 PW-8150 Fixed options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

How do the 25C sunset and pre-1978 Lead RRP rules affect PW-8150 Fixed?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Custom Window Systems, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do you cross-check NFRC CWS and product line CWS-K-23 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code CWS and product line CWS-K-23, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Custom Window Systems, Inc. PW-8150 Fixed come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros