Skip to main content
Window · Vinyl Frame NFRC MAG · Product Line MAG-A-33

Magnolia Window and Door — 400/4000 Single Hung · Single Hung

With a minimum U-Factor of 0.25—+0.05 compared against the 0.20 Window median—Magnolia Window and Door 400/4000 Single Hung spans 228 tested options across North-Central, South-Central, Southern up to 0.30 U-Factor. Carrying NFRC CPD code MAG, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.16 and 0.22.

Min U-Factor
0.25
SHGC Range
0.16-0.22
Certified Options
228
Category Standing
#1,174 of 1,352

How does Magnolia Window and Door 400/4000 Single Hung compare thermally against Window peers?

Magnolia Window and Door 400/4000 Single Hung achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 400/4000 Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing 400/4000 Single Hung (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

400/4000 Single Hung Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Magnolia Window and Door 400/4000 Single Hung standing at #1,174 of 1,352 certified Window product series, tied with 81 others at 0.25, more insulating than 7.2% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.06 before selecting Low-E tiers.

Regional qualification covers North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.16 lowers cooling load.

Lifecycle documentation anchors MAG to 2025-05-21 certification (FENSTAR issued 2018-03-28). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 150.0 BTU/hr conductive loss (+13.6% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 228 certified glazing combinations for 400/4000 Single Hung (NFRC MAG) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 57 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 135 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 228 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Magnolia Window and Door produce?

Compare other active Magnolia Window and Door certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Magnolia Window and Door 400/4000 Single Hung appear below.

Where does Magnolia Window and Door 400/4000 Single Hung stand thermally among ENERGY STAR Window lines?

Across 228 tested NFRC glazing configurations, Magnolia Window and Door 400/4000 Single Hung with Vinyl framing and Single-Hung (VSSH) style reaches a 0.25 minimum U-Factor and 0.16-0.22 SHGC band. It places #1,174 among 1,352 Window series—more insulating than 7.2%.

Is 400/4000 Single Hung approved for Northern Zone heating climates?

No—with 0 Northern packages and a 0.25 thermal floor, Magnolia Window and Door 400/4000 Single Hung targets warmer North-Central, South-Central, Southern climates instead of cold Northern installations.

What BTU/hr heat transfer results from 400/4000 Single Hung's 0.25 minimum U-Factor?

At U 0.25, a standard 3x5 ft (15 sq ft) 400/4000 Single Hung opening transfers 150.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +18.0 BTU/hr difference.

What are the practical limitations of specifying 400/4000 Single Hung?

Do not specify 400/4000 Single Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 400/4000 Single Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

How many 400/4000 Single Hung glazing packages pass Southern solar-heat rules?

Exactly 228 400/4000 Single Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.16 rather than higher 0.22 glass.

Which package tier in 400/4000 Single Hung holds Most Efficient recognition?

All 228 400/4000 Single Hung listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

What 2026 federal tax credit and Lead RRP rules apply to 400/4000 Single Hung?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do building inspectors verify 400/4000 Single Hung glass specs on job sites?

Match the NFRC thermal sticker for code MAG and line MAG-A-33 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Magnolia Window and Door 400/4000 Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros