Skip to main content
Window · Vinyl Frame NFRC SIE · Product Line SIE-N-120

Sierra Pacific Windows — Vinyl Builders Single Hung · Single Hung

Sierra Pacific Windows Vinyl Builders Single Hung is a Single Hung assembly with a Vinyl frame that reaches a minimum U-Factor of 0.25 across 268 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #1,174 of 1,352 in Window, its thermal floor is 0.05 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.12 to 0.50.

Min U-Factor
0.25
SHGC Range
0.12-0.50
Certified Options
268
Category Standing
#1,174 of 1,352

How does Sierra Pacific Windows Vinyl Builders Single Hung compare thermally against Window peers?

Sierra Pacific Windows Vinyl Builders Single Hung achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Vinyl Builders Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Vinyl Builders Single Hung (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Vinyl Builders Single Hung Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), Vinyl Builders Single Hung reaches 0.25 on its lowest-conductivity package — #907 of 1,009 in Vinyl, tied with 49 others at 0.25, more insulating than 5.3% of Vinyl lines (+0.06 vs Vinyl peers). Pairing NFRC ID SIE across multi-pane fills shifts U-Factor from 0.32 down toward 0.25.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 4 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2024-04-13 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 150.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 268 certified glazing combinations for Vinyl Builders Single Hung (NFRC SIE) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 4 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 7 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 101 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 264 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Sierra Pacific Windows produce?

Compare other active Sierra Pacific Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Sierra Pacific Windows Vinyl Builders Single Hung appear below.

What U-Factor and SHGC range does Sierra Pacific Windows Vinyl Builders Single Hung achieve?

EPA ENERGY STAR v7.0 records 268 configurations for Sierra Pacific Windows Vinyl Builders Single Hung covering Northern, North-Central, South-Central, Southern, dropping down to U 0.25 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Can homeowners install Vinyl Builders Single Hung in cold Northern ENERGY STAR counties?

Prescriptive Northern approval ends at U <= 0.22, above Vinyl Builders Single Hung's 0.25 minimum. However, 4 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

How do you calculate winter heat conduction for Sierra Pacific Windows Vinyl Builders Single Hung?

At U 0.25, a standard 3x5 ft (15 sq ft) Vinyl Builders Single Hung opening transfers 150.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +18.0 BTU/hr difference.

What are the practical limitations of specifying Vinyl Builders Single Hung?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Vinyl Builders Single Hung options exceeding U 0.22. Additionally, do not order Single-Hung (VSSH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

How many Vinyl Builders Single Hung glazing packages pass Southern solar-heat rules?

Exactly 264 Vinyl Builders Single Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.12 rather than higher 0.50 glass.

How many Sierra Pacific Windows Vinyl Builders Single Hung variants earn ENERGY STAR Most Efficient?

No. Zero of the 268 configurations in Sierra Pacific Windows Vinyl Builders Single Hung hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

What 2026 federal tax credit and Lead RRP rules apply to Vinyl Builders Single Hung?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Sierra Pacific Windows upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

What permanent glass etch marks verify Vinyl Builders Single Hung after sticker removal?

Verify NFRC ID SIE and series SIE-N-120 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Sierra Pacific Windows Vinyl Builders Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros