Skip to main content
Window · Vinyl Frame NFRC WLR · Product Line WLR-A-3

Westlake Royal Windows LLC — 700 Horizontal Slider · Single Slider

With a minimum U-Factor of 0.25—+0.05 compared against the 0.20 Window median—Westlake Royal Windows LLC 700 Horizontal Slider spans 275 tested options across North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code WLR, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.16 and 0.22.

Min U-Factor
0.25
SHGC Range
0.16-0.22
Certified Options
275
Category Standing
#1,174 of 1,352

How does Westlake Royal Windows LLC 700 Horizontal Slider compare thermally against Window peers?

Westlake Royal Windows LLC 700 Horizontal Slider achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 700 Horizontal SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing 700 Horizontal Slider (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

700 Horizontal Slider Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 700 Horizontal Slider spans 275 NFRC test records (WLR), ranking #1,174 of 1,352 Window families (tied with 81 others at 0.25, more insulating than 7.2% of Window lines). Its 0.25 thermal floor compares at +0.06 against the Vinyl median (0.19).

Regional qualification covers North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.16 lowers cooling load.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.25 U-Factor yields 150.0 BTU/hr transfer (+18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2023-05-31 licensing and 2025-07-24 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 275 certified glazing combinations for 700 Horizontal Slider (NFRC WLR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 48 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 126 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 275 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Westlake Royal Windows LLC produce?

Compare other active Westlake Royal Windows LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Westlake Royal Windows LLC 700 Horizontal Slider appear below.

What U-Factor and SHGC range does Westlake Royal Windows LLC 700 Horizontal Slider achieve?

Westlake Royal Windows LLC 700 Horizontal Slider spans 275 certified configurations with U-Factors between 0.25 and 0.32 and SHGC values from 0.16 to 0.22. Ranked #1,174 of 1,352 Window families, it carries 0 Most Efficient options.

How does Westlake Royal Windows LLC 700 Horizontal Slider satisfy Version 7.0 Northern criteria?

No—with 0 Northern packages and a 0.25 thermal floor, Westlake Royal Windows LLC 700 Horizontal Slider targets warmer North-Central, South-Central, Southern climates instead of cold Northern installations.

How do you calculate winter heat conduction for Westlake Royal Windows LLC 700 Horizontal Slider?

Using NFRC WLR U-Factor 0.25, a 15 sq ft Horizontal Slider (HSOX) assembly conducts 150.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+18.0 BTU/hr margin).

When should a buyer skip Westlake Royal Windows LLC 700 Horizontal Slider and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 700 Horizontal Slider options exceeding U 0.22. Additionally, do not order Horizontal Slider (HSOX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Does 700 Horizontal Slider meet Southern hot-climate SHGC caps (<= 0.23)?

Across North-Central, South-Central, Southern, 275 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Westlake Royal Windows LLC 700 Horizontal Slider, while total line SHGC reaches 0.22 in colder packages.

Does 700 Horizontal Slider carry EPA Most Efficient certification across its lineup?

ENERGY STAR Most Efficient designation is absent across all 275 700 Horizontal Slider options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

What 2026 federal tax credit and Lead RRP rules apply to 700 Horizontal Slider?

Any 700 Horizontal Slider purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How can homeowners confirm delivered Westlake Royal Windows LLC 700 Horizontal Slider units match permits?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code WLR and product line WLR-A-3, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Westlake Royal Windows LLC 700 Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros