Skip to main content
Window · Vinyl Frame NFRC WLR · Product Line WLR-A-2

Westlake Royal Windows LLC — 700 Single Hung · Single Hung

With a minimum U-Factor of 0.24—+0.04 compared against the 0.20 Window median—Westlake Royal Windows LLC 700 Single Hung spans 405 tested options across North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code WLR, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.16 and 0.22.

Min U-Factor
0.24
SHGC Range
0.16-0.22
Certified Options
405
Category Standing
#1,034 of 1,352

How does Westlake Royal Windows LLC 700 Single Hung compare thermally against Window peers?

Westlake Royal Windows LLC 700 Single Hung achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 700 Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 700 Single Hung (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

700 Single Hung Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 7 certified Westlake Royal Windows LLC series, this Single Hung offers a 0.08 U-Factor adjustment span between 0.32 entry options and 0.24 top-performing glazing. Category standing is #1,034/1,352 (tied with 139 others at 0.24, more insulating than 13.2% of Window lines).

Evaluating climate compliance across North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.16 lowers cooling load.

Data provenance links certification 2026-01-07 and FENSTAR license 2023-05-31 inside EPA Version 7.0 tables. Heat transfer computes to 144.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 405 certified glazing combinations for 700 Single Hung (NFRC WLR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 69 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 208 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 405 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Thermo-Tech Windows — 7600 Double Hung Vinyl 0.24 0.15 404
Quaker Window Products — V100 Horizontal Slider Vinyl 0.24 0.14 410
Quaker Window Products — V100 Single Hung Vinyl 0.24 0.14 398
MGM Industries — 6010 Horizontal Slider Vinyl 0.24 0.13 382
JELD-WEN, inc. — Premium Altantic Vinyl Horizontal Slider Vinyl 0.24 0.13 429

What other certified series does Westlake Royal Windows LLC produce?

Compare other active Westlake Royal Windows LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Westlake Royal Windows LLC 700 Single Hung appear below.

What U-Factor and SHGC range does Westlake Royal Windows LLC 700 Single Hung achieve?

EPA ENERGY STAR v7.0 records 405 configurations for Westlake Royal Windows LLC 700 Single Hung covering North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Is 700 Single Hung approved for Northern Zone heating climates?

No—with 0 Northern packages and a 0.24 thermal floor, Westlake Royal Windows LLC 700 Single Hung targets warmer North-Central, South-Central, Southern climates instead of cold Northern installations.

How do you calculate winter heat conduction for Westlake Royal Windows LLC 700 Single Hung?

At U 0.24, a standard 3x5 ft (15 sq ft) 700 Single Hung opening transfers 144.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +12.0 BTU/hr difference.

Who should NOT choose Westlake Royal Windows LLC 700 Single Hung for a residential project?

Do not specify 700 Single Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 700 Single Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

What Southern ENERGY STAR v7.0 options exist in 700 Single Hung?

Exactly 405 700 Single Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.16 rather than higher 0.22 glass.

Are all 405 700 Single Hung configurations ENERGY STAR Most Efficient?

Zero glazing builds inside 700 Single Hung's 405 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

Can homeowners claim Form 5695 credits on Westlake Royal Windows LLC 700 Single Hung in 2026?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 700 Single Hung retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do you cross-check NFRC WLR and product line WLR-A-2 on delivery?

Match the NFRC thermal sticker for code WLR and line WLR-A-2 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Westlake Royal Windows LLC 700 Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros