Skip to main content
Window · Vinyl Frame NFRC JEL · Product Line JEL-A-707

JELD-WEN, inc. — Premium Altantic Vinyl Horizontal Slider · Single Slider

With a minimum U-Factor of 0.24—+0.04 compared against the 0.20 Window median—JELD-WEN, inc. Premium Altantic Vinyl Horizontal Slider spans 429 tested options across North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code JEL, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.13 and 0.29.

Min U-Factor
0.24
SHGC Range
0.13-0.29
Certified Options
429
Category Standing
#1,034 of 1,352

How does JELD-WEN, inc. Premium Altantic Vinyl Horizontal Slider compare thermally against Window peers?

JELD-WEN, inc. Premium Altantic Vinyl Horizontal Slider achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Premium Altantic Vinyl Horizontal SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Premium Altantic Vinyl Horizontal Slider (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Premium Altantic Vinyl Horizontal Slider Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places JELD-WEN, inc. Premium Altantic Vinyl Horizontal Slider at rank #1,034 of 1,352 (tied with 139 others at 0.24, more insulating than 13.2% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.13-0.29 band.

Evaluating climate compliance across North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.13 lowers cooling load.

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-05-23. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.24 conducts 144.0 BTU/hr (+12.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 429 certified glazing combinations for Premium Altantic Vinyl Horizontal Slider (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 16 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 96 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 421 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Premium Altantic Vinyl Horizontal Slider appear below.

How efficient is JELD-WEN, inc. Premium Altantic Vinyl Horizontal Slider compared with peer Window models?

EPA ENERGY STAR v7.0 records 429 configurations for JELD-WEN, inc. Premium Altantic Vinyl Horizontal Slider covering North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Which glazing options in JELD-WEN, inc. Premium Altantic Vinyl Horizontal Slider meet Northern climate limits?

JELD-WEN, inc. Premium Altantic Vinyl Horizontal Slider holds zero Northern Zone qualifications (min U 0.24). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

What BTU/hr heat transfer results from Premium Altantic Vinyl Horizontal Slider's 0.24 minimum U-Factor?

At U 0.24, a standard 3x5 ft (15 sq ft) Premium Altantic Vinyl Horizontal Slider opening transfers 144.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +12.0 BTU/hr difference.

What homeowner profiles are a poor match for JELD-WEN, inc. Premium Altantic Vinyl Horizontal Slider?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Premium Altantic Vinyl Horizontal Slider options exceeding U 0.22. Additionally, do not order Horizontal Slider (HSOX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Does Premium Altantic Vinyl Horizontal Slider meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 421 Southern-approved options within Premium Altantic Vinyl Horizontal Slider spanning SHGC down to 0.13. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Does Premium Altantic Vinyl Horizontal Slider carry EPA Most Efficient certification across its lineup?

No. Zero of the 429 configurations in JELD-WEN, inc. Premium Altantic Vinyl Horizontal Slider hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

What 2026 federal tax credit and Lead RRP rules apply to Premium Altantic Vinyl Horizontal Slider?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Premium Altantic Vinyl Horizontal Slider installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How can homeowners confirm delivered JELD-WEN, inc. Premium Altantic Vinyl Horizontal Slider units match permits?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code JEL and product line JEL-A-707, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Premium Altantic Vinyl Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros