Window · Vinyl Frame NFRC KRM · Product Line KRM-A-17

Krestmark Industries L. P. — 400/4000 Horizontal Slider · Single Slider

EPA ENERGY STAR Version 7.0 certifies 433 variants inside Krestmark Industries L. P. 400/4000 Horizontal Slider, combining Vinyl frame construction with U-Factors spanning 0.24 to 0.32 and SHGC 0.17 to 0.23. Qualifying for North-Central, South-Central, Southern, this Single Slider family places #1,034 of 1,352 among 1,352 Window families and posts 0.05 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.24
SHGC Range
0.17-0.23
Certified Options
433
Category Standing
#1,034 of 1,352

How does Krestmark Industries L. P. 400/4000 Horizontal Slider compare thermally against Window peers?

Krestmark Industries L. P. 400/4000 Horizontal Slider achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 400/4000 Horizontal SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 400/4000 Horizontal Slider (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

400/4000 Horizontal Slider Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 11 certified Krestmark Industries L. P. series, this Single Slider offers a 0.08 U-Factor adjustment span between 0.32 entry options and 0.24 top-performing glazing. Category standing is #1,034/1,352 (tied with 139 others at 0.24, more insulating than 13.2% of Window lines).

Mapping NFRC SHGC values (0.17 to 0.23) against ENERGY STAR Version 7.0 targets approves North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.17 lowers cooling load.

Lifecycle documentation anchors KRM to 2023-12-19 certification (FENSTAR issued 2018-09-05). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 144.0 BTU/hr conductive loss (+9.1% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 433 certified glazing combinations for 400/4000 Horizontal Slider (NFRC KRM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 118 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 270 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 433 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Krestmark Industries L. P. produce?

Compare other active Krestmark Industries L. P. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Krestmark Industries L. P. 400/4000 Horizontal Slider appear below.

What U-Factor and SHGC range does Krestmark Industries L. P. 400/4000 Horizontal Slider achieve?

EPA ENERGY STAR v7.0 records 433 configurations for Krestmark Industries L. P. 400/4000 Horizontal Slider covering North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Can homeowners install 400/4000 Horizontal Slider in cold Northern ENERGY STAR counties?

No. Because 400/4000 Horizontal Slider reaches only 0.24 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Vinyl line strictly across North-Central, South-Central, Southern cooling or mixed markets.

How much winter heat loss does 400/4000 Horizontal Slider conduct across a 15 sq ft opening?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 144.0 BTU/hr on 400/4000 Horizontal Slider's lowest-U package (0.24), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

When should a buyer skip Krestmark Industries L. P. 400/4000 Horizontal Slider and compare alternatives?

Do not specify 400/4000 Horizontal Slider without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 400/4000 Horizontal Slider options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Is 400/4000 Horizontal Slider suitable for sunbelt cooling-dominated homes?

Exactly 433 400/4000 Horizontal Slider options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.17 rather than higher 0.23 glass.

How many Krestmark Industries L. P. 400/4000 Horizontal Slider variants earn ENERGY STAR Most Efficient?

Zero glazing builds inside 400/4000 Horizontal Slider's 433 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

How do the 25C sunset and pre-1978 Lead RRP rules affect 400/4000 Horizontal Slider?

Any 400/4000 Horizontal Slider purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do you cross-check NFRC KRM and product line KRM-A-17 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line KRM-A-17 and NFRC ID KRM before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Krestmark Industries L. P. 400/4000 Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)