Krestmark Industries L. P. — 400/4000 PW · Picture Window
Across 11 Krestmark Industries L. P. certified families, 400/4000 PW supplies 576 Picture Window configurations starting at 0.21 U-Factor and 0.19 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.25 SHGC. Its thermal floor ranks #742 of 1,352 category entries—0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.21
- SHGC Range
- 0.19-0.25
- Certified Options
- 576
- Category Standing
- #742 of 1,352
How does Krestmark Industries L. P. 400/4000 PW compare thermally against Window peers?
Krestmark Industries L. P. 400/4000 PW achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Vinyl cohort (0.19 median U-Factor), 400/4000 PW reaches 0.21 on its lowest-conductivity package — #561 of 1,009 in Vinyl, tied with 78 others at 0.21, more insulating than 36.7% of Vinyl lines (+0.02 vs Vinyl peers). Pairing NFRC ID KRM across multi-pane fills shifts U-Factor from 0.32 down toward 0.21.
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 97 configurations meet ENERGY STAR Most Efficient criteria while 157 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 126.0 BTU/hr (-4.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-09-05 and cert timestamp 2026-01-14.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 576 certified glazing combinations for 400/4000 PW (NFRC KRM) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 157 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 288 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 358 packages (0 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 512 packages (97 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| A Window, Inc. — SL3 Series Picture Window (16059 Frame) | Vinyl | 0.21 | 0.18 | 575 |
| Atrium Companies, Inc. — 450/455/460/465 PW | Vinyl | 0.21 | 0.16 | 579 |
| A Window, Inc. — V-25 PW | Vinyl | 0.21 | 0.16 | 627 |
| A Window, Inc. — V-31 PW | Vinyl | 0.21 | 0.16 | 627 |
| Windsor Windows and Doors — Next Dimension Signature Radius and Direct Set | Vinyl | 0.21 | 0.13 | 518 |
What other certified series does Krestmark Industries L. P. produce?
Compare other active Krestmark Industries L. P. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Krestmark Industries L. P. 400/4000 PW appear below.
Where does Krestmark Industries L. P. 400/4000 PW stand thermally among ENERGY STAR Window lines?
Across 576 tested NFRC glazing configurations, Krestmark Industries L. P. 400/4000 PW with Vinyl framing and Fixed Window (FIXD) style reaches a 0.21 minimum U-Factor and 0.19-0.25 SHGC band. It places #742 among 1,352 Window series—more insulating than 38.6%.
Can homeowners install 400/4000 PW in cold Northern ENERGY STAR counties?
Yes, 157 packages satisfy Northern ENERGY STAR Version 7.0 rules in 400/4000 PW. Pairing multi-pane insulation down to 0.21 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.
How does a 3x5 ft 400/4000 PW window perform under a 40 deg F temperature drop?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 400/4000 PW at U 0.21 conducts 126.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
When should a buyer skip Krestmark Industries L. P. 400/4000 PW and compare alternatives?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 400/4000 PW options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Can you install Krestmark Industries L. P. 400/4000 PW in Southern or South-Central zones?
Yes. 512 Southern-certified options inside Krestmark Industries L. P. 400/4000 PW satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.25 SHGC on west-facing glass to avoid excess afternoon solar gain.
Does 400/4000 PW carry EPA Most Efficient certification across its lineup?
Not every package qualifies: 97 of 576 400/4000 PW glazing builds earn Most Efficient recognition (16.8%), while other variants sit on the standard Version 7.0 tier.
Do 2026 400/4000 PW installations qualify for IRS Section 25C tax credits?
Any 400/4000 PW purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
What permanent glass etch marks verify 400/4000 PW after sticker removal?
Match the NFRC thermal sticker for code KRM and line KRM-A-16 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Krestmark Industries L. P. 400/4000 PW come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)