Skip to main content
Window · Vinyl Frame NFRC AWN · Product Line AWN-M-5 ENERGY STAR Most Efficient Eligible

A Window, Inc. — V-25 PW · Picture Window

Positioning #742/1,352 in certified Window, A Window, Inc. V-25 PW pairs Vinyl frame construction with 627 glazing options rated between 0.16 and 0.32 SHGC across Northern, North-Central, South-Central, Southern. Across 10 certified A Window, Inc. product families, its thermal resistance spans 0.21 to 0.32 U-Factor and the line includes 50 ENERGY STAR Most Efficient packages (8.0% of line).

Min U-Factor
0.21
SHGC Range
0.16-0.32
Certified Options
627
Category Standing
#742 of 1,352

How does A Window, Inc. V-25 PW compare thermally against Window peers?

A Window, Inc. V-25 PW achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. V-25 PWHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing V-25 PW (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

V-25 PW Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows A Window, Inc. V-25 PW standing at #742 of 1,352 certified Window product series, tied with 88 others at 0.21, more insulating than 38.6% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.02 before selecting Low-E tiers.

Regional qualification covers Northern, North-Central, South-Central, Southern. 50 configurations meet ENERGY STAR Most Efficient criteria while 96 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 126.0 BTU/hr (-4.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-09-13.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 627 certified glazing combinations for V-25 PW (NFRC AWN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 96 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 314 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 396 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 528 packages (50 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does A Window, Inc. produce?

Compare other active A Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to A Window, Inc. V-25 PW appear below.

Where does A Window, Inc. V-25 PW stand thermally among ENERGY STAR Window lines?

A Window, Inc. V-25 PW spans 627 certified configurations with U-Factors between 0.21 and 0.32 and SHGC values from 0.16 to 0.32. Ranked #742 of 1,352 Window families, it carries 50 Most Efficient options.

Which glazing options in A Window, Inc. V-25 PW meet Northern climate limits?

Prescriptive Northern compliance covers 96 V-25 PW packages (U floor 0.21, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

What conductive BTU/hr difference separates V-25 PW from the 0.22 Northern rule?

Using NFRC AWN U-Factor 0.21, a 15 sq ft Fixed Window (FIXD) assembly conducts 126.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-6.0 BTU/hr margin).

What homeowner profiles are a poor match for A Window, Inc. V-25 PW?

Cold-climate owners needing prescriptive U <= 0.22 should pass on V-25 PW options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

How many V-25 PW glazing packages pass Southern solar-heat rules?

Yes, V-25 PW holds 528 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.16 SHGC in cooling climates.

Are all 627 V-25 PW configurations ENERGY STAR Most Efficient?

Only 50 options out of 627 (8.0%) meet tighter Most Efficient U-Factor and SHGC thresholds in A Window, Inc. V-25 PW, usually requiring triple-pane or upgraded Low-E coatings.

How do the 25C sunset and pre-1978 Lead RRP rules affect V-25 PW?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 A Window, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

Where are NFRC and IGCC identification marks located on V-25 PW?

Verify NFRC ID AWN and series AWN-M-5 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for A Window, Inc. V-25 PW come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros