A Window, Inc. — V-25 PW · Picture Window
Positioning #742/1,352 in certified Window, A Window, Inc. V-25 PW pairs Vinyl frame construction with 627 glazing options rated between 0.16 and 0.32 SHGC across Northern, North-Central, South-Central, Southern. Across 10 certified A Window, Inc. product families, its thermal resistance spans 0.21 to 0.32 U-Factor and the line includes 50 ENERGY STAR Most Efficient packages (8.0% of line).
- Min U-Factor
- 0.21
- SHGC Range
- 0.16-0.32
- Certified Options
- 627
- Category Standing
- #742 of 1,352
How does A Window, Inc. V-25 PW compare thermally against Window peers?
A Window, Inc. V-25 PW achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows A Window, Inc. V-25 PW standing at #742 of 1,352 certified Window product series, tied with 88 others at 0.21, more insulating than 38.6% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.02 before selecting Low-E tiers.
Regional qualification covers Northern, North-Central, South-Central, Southern. 50 configurations meet ENERGY STAR Most Efficient criteria while 96 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 126.0 BTU/hr (-4.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-09-13.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 627 certified glazing combinations for V-25 PW (NFRC AWN) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 96 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 314 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 396 packages (0 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 528 packages (50 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Atrium Companies, Inc. — 450/455/460/465 PW | Vinyl | 0.21 | 0.16 | 579 |
| Krestmark Industries L. P. — 400/4000 PW | Vinyl | 0.21 | 0.19 | 576 |
| Silver Line Building Products — 3050/3950 Picture Window & Shapes | Vinyl | 0.21 | 0.18 | 699 |
| Windsor Windows and Doors — Next Dimension Signature Radius and Direct Set | Vinyl | 0.21 | 0.13 | 518 |
| Westlake Royal Windows LLC — 250 Fixed | Vinyl | 0.21 | 0.18 | 503 |
What other certified series does A Window, Inc. produce?
Compare other active A Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
SL3 Series Picture Window (15997 Frame)
U-Factor 0.21–0.32 · 477 certified options.
SL3 Series Picture Window (16059 Frame)
U-Factor 0.21–0.32 · 575 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to A Window, Inc. V-25 PW appear below.
Where does A Window, Inc. V-25 PW stand thermally among ENERGY STAR Window lines?
A Window, Inc. V-25 PW spans 627 certified configurations with U-Factors between 0.21 and 0.32 and SHGC values from 0.16 to 0.32. Ranked #742 of 1,352 Window families, it carries 50 Most Efficient options.
Which glazing options in A Window, Inc. V-25 PW meet Northern climate limits?
Prescriptive Northern compliance covers 96 V-25 PW packages (U floor 0.21, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.
What conductive BTU/hr difference separates V-25 PW from the 0.22 Northern rule?
Using NFRC AWN U-Factor 0.21, a 15 sq ft Fixed Window (FIXD) assembly conducts 126.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-6.0 BTU/hr margin).
What homeowner profiles are a poor match for A Window, Inc. V-25 PW?
Cold-climate owners needing prescriptive U <= 0.22 should pass on V-25 PW options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
How many V-25 PW glazing packages pass Southern solar-heat rules?
Yes, V-25 PW holds 528 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.16 SHGC in cooling climates.
Are all 627 V-25 PW configurations ENERGY STAR Most Efficient?
Only 50 options out of 627 (8.0%) meet tighter Most Efficient U-Factor and SHGC thresholds in A Window, Inc. V-25 PW, usually requiring triple-pane or upgraded Low-E coatings.
How do the 25C sunset and pre-1978 Lead RRP rules affect V-25 PW?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 A Window, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
Where are NFRC and IGCC identification marks located on V-25 PW?
Verify NFRC ID AWN and series AWN-M-5 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for A Window, Inc. V-25 PW come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)