Skip to main content
Window · Vinyl Frame NFRC AWN · Product Line AWN-M-6

A Window, Inc. — V-25/31 SH · Single Hung

With a minimum U-Factor of 0.24—+0.04 compared against the 0.20 Window median—A Window, Inc. V-25/31 SH spans 980 tested options across North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code AWN, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.15 and 0.30.

Min U-Factor
0.24
SHGC Range
0.15-0.30
Certified Options
980
Category Standing
#1,034 of 1,352

How does A Window, Inc. V-25/31 SH compare thermally against Window peers?

A Window, Inc. V-25/31 SH achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. V-25/31 SHHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing V-25/31 SH (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

V-25/31 SH Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across V-25/31 SH spans 980 NFRC test records (AWN), ranking #1,034 of 1,352 Window families (tied with 139 others at 0.24, more insulating than 13.2% of Window lines). Its 0.24 thermal floor compares at +0.05 against the Vinyl median (0.19).

Climate coverage for A Window, Inc. V-25/31 SH spans North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.15 lowers cooling load.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.24 U-Factor yields 144.0 BTU/hr transfer (+12.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-07-02 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 980 certified glazing combinations for V-25/31 SH (NFRC AWN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 214 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 520 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 942 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Seaway Manufacturing Corporation — Amerivu Single Hung Vinyl 0.24 0.13 1,062
YKK AP America, Inc. — Precedence Horizontal Slider Vinyl 0.24 0.18 884
Amsco Windows — V2K Basement Window Vinyl 0.24 0.13 1,114
Atrium Companies, Inc. — 450/455/460/465 DH Vinyl 0.24 0.15 805
YKK AP America, Inc. — Style View Single Slider Vinyl 0.24 0.19 803

What other certified series does A Window, Inc. produce?

Compare other active A Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to A Window, Inc. V-25/31 SH appear below.

What U-Factor and SHGC range does A Window, Inc. V-25/31 SH achieve?

Built with Vinyl framing in Single-Hung (VSSH) style, A Window, Inc. V-25/31 SH offers 980 Version 7.0 configurations from U 0.24 up to 0.32, posting +0.04 against the Window median of 0.20 with 0 Most Efficient picks.

Does A Window, Inc. V-25/31 SH qualify for the ENERGY STAR Northern Zone?

Northern Zone certification is absent for V-25/31 SH (0 qualifying options, min U 0.24). Install this Single-Hung (VSSH) product only within North-Central, South-Central, Southern regions where lower SHGC caps apply.

How much winter heat loss does V-25/31 SH conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.24 U-Factor yields 144.0 BTU/hr conductive transfer (+9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What are the practical limitations of specifying V-25/31 SH?

Skip V-25/31 SH if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on V-25/31 SH options exceeding U 0.22.

Can you install A Window, Inc. V-25/31 SH in Southern or South-Central zones?

Warm-climate homeowners have 942 Southern-approved options within V-25/31 SH spanning SHGC down to 0.15. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Does V-25/31 SH carry EPA Most Efficient certification across its lineup?

V-25/31 SH holds zero Most Efficient entries across its 980 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

How do the 25C sunset and pre-1978 Lead RRP rules affect V-25/31 SH?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current V-25/31 SH retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

What permanent glass etch marks verify V-25/31 SH after sticker removal?

Inspectors match the temporary NFRC sticker (U 0.24-0.32, SHGC 0.15-0.30) against permit drawings for line AWN-M-6. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for A Window, Inc. V-25/31 SH come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)