Atrium Companies, Inc. — 450/455/460/465 DH · Double Hung
Across 10 Atrium Companies, Inc. certified families, 450/455/460/465 DH supplies 805 Double Hung configurations starting at 0.24 U-Factor and 0.15 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.47 SHGC. Its thermal floor ranks #1,034 of 1,352 category entries—0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.24
- SHGC Range
- 0.15-0.47
- Certified Options
- 805
- Category Standing
- #1,034 of 1,352
How does Atrium Companies, Inc. 450/455/460/465 DH compare thermally against Window peers?
Atrium Companies, Inc. 450/455/460/465 DH achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Vinyl cohort (0.19 median U-Factor), 450/455/460/465 DH reaches 0.24 on its lowest-conductivity package — #798 of 1,009 in Vinyl, tied with 108 others at 0.24, more insulating than 10.2% of Vinyl lines (+0.05 vs Vinyl peers). Pairing NFRC ID ADW across multi-pane fills shifts U-Factor from 0.32 down toward 0.24.
Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 40 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Data provenance links certification 2025-01-09 and FENSTAR license 2018-10-03 inside EPA Version 7.0 tables. Heat transfer computes to 144.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 805 certified glazing combinations for 450/455/460/465 DH (NFRC ADW) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 40 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 96 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 356 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 743 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| YKK AP America, Inc. — Style View Single Slider | Vinyl | 0.24 | 0.19 | 803 |
| Vinylmax LLC — SH46 Single Slider | Vinyl | 0.24 | 0.19 | 753 |
| YKK AP America, Inc. — Precedence Horizontal Slider | Vinyl | 0.24 | 0.18 | 884 |
| Vinylmax LLC — SH46 Single Hung | Vinyl | 0.24 | 0.19 | 690 |
| A Window, Inc. — V-25/31 SS | Vinyl | 0.24 | 0.15 | 970 |
What other certified series does Atrium Companies, Inc. produce?
Compare other active Atrium Companies, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
8900/90/8000/1800/8900 Picture Window
U-Factor 0.15–0.31 · 312 certified options.
8900/90/8000/1800/3900 Double Slider
U-Factor 0.17–0.32 · 474 certified options.
8300/8700/1300/1600/3201/3500/40/80/3000/6000 Picture Window
U-Factor 0.21–0.31 · 1,710 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Atrium Companies, Inc. 450/455/460/465 DH appear below.
What U-Factor and SHGC range does Atrium Companies, Inc. 450/455/460/465 DH achieve?
EPA ENERGY STAR v7.0 records 805 configurations for Atrium Companies, Inc. 450/455/460/465 DH covering Northern, North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.20 Window median. Only 0 options earn Most Efficient status.
Does Atrium Companies, Inc. 450/455/460/465 DH qualify for the ENERGY STAR Northern Zone?
Because 450/455/460/465 DH starts at 0.24 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 40 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).
What BTU/hr heat transfer results from 450/455/460/465 DH's 0.24 minimum U-Factor?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 144.0 BTU/hr on 450/455/460/465 DH's lowest-U package (0.24), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.
Which situations make 450/455/460/465 DH the wrong window or door choice?
Skip 450/455/460/465 DH if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 450/455/460/465 DH options exceeding U 0.22.
What Southern ENERGY STAR v7.0 options exist in 450/455/460/465 DH?
Across Northern, North-Central, South-Central, Southern, 743 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Atrium Companies, Inc. 450/455/460/465 DH, while total line SHGC reaches 0.47 in colder packages.
Are all 805 450/455/460/465 DH configurations ENERGY STAR Most Efficient?
450/455/460/465 DH holds zero Most Efficient entries across its 805 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.
What 2026 federal tax credit and Lead RRP rules apply to 450/455/460/465 DH?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 450/455/460/465 DH installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
Where are NFRC and IGCC identification marks located on 450/455/460/465 DH?
Match the NFRC thermal sticker for code ADW and line ADW-M-406 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Atrium Companies, Inc. 450/455/460/465 DH come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)