Skip to main content
Window · Vinyl Frame NFRC VIM · Product Line VIM-M-28

Vinylmax LLC — SH46 Single Slider · Single Slider

Vinylmax LLC engineered the SH46 Single Slider Single Slider line for Northern, North-Central, South-Central, Southern, certifying 753 glass-spacer combinations from 0.24 to 0.32 U-Factor and 0.19 to 0.51 SHGC. Relative to other Vinyl models tracked under NFRC VIM, its minimum U-Factor is 0.05 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.24
SHGC Range
0.19-0.51
Certified Options
753
Category Standing
#1,034 of 1,352

How does Vinylmax LLC SH46 Single Slider compare thermally against Window peers?

Vinylmax LLC SH46 Single Slider achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. SH46 Single SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing SH46 Single Slider (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

SH46 Single Slider Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Vinylmax LLC SH46 Single Slider standing at #1,034 of 1,352 certified Window product series, tied with 139 others at 0.24, more insulating than 13.2% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.05 before selecting Low-E tiers.

Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 104 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2024-02-26 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 144.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 753 certified glazing combinations for SH46 Single Slider (NFRC VIM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 104 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 188 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 334 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 565 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Vinylmax LLC produce?

Compare other active Vinylmax LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Vinylmax LLC SH46 Single Slider appear below.

How well does SH46 Single Slider by Vinylmax LLC insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 753 configurations for Vinylmax LLC SH46 Single Slider covering Northern, North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Which glazing options in Vinylmax LLC SH46 Single Slider meet Northern climate limits?

Northern qualification on SH46 Single Slider relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.24. Exactly 104 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

How does a 3x5 ft SH46 Single Slider window perform under a 40 deg F temperature drop?

Using NFRC VIM U-Factor 0.24, a 15 sq ft Horizontal Slider (HSOX) assembly conducts 144.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+12.0 BTU/hr margin).

Who should NOT choose Vinylmax LLC SH46 Single Slider for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on SH46 Single Slider options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Does SH46 Single Slider meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 565 Southern-certified options inside Vinylmax LLC SH46 Single Slider satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.51 SHGC on west-facing glass to avoid excess afternoon solar gain.

What glazing share inside SH46 Single Slider qualifies as Most Efficient?

No. Zero of the 753 configurations in Vinylmax LLC SH46 Single Slider hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

What 2026 federal tax credit and Lead RRP rules apply to SH46 Single Slider?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do building inspectors verify SH46 Single Slider glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line VIM-M-28 and NFRC ID VIM before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Vinylmax LLC SH46 Single Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros