Skip to main content
Window · Vinyl Frame NFRC ADW · Product Line ADW-M-389 ENERGY STAR Most Efficient Eligible

Atrium Companies, Inc. — 8900/90/8000/1800/3900 Double Slider · Double Slider

Atrium Companies, Inc. 8900/90/8000/1800/3900 Double Slider is a Double Slider assembly with a Vinyl frame that reaches a minimum U-Factor of 0.17 across 474 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #362 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.14 to 0.23.

Min U-Factor
0.17
SHGC Range
0.14-0.23
Certified Options
474
Category Standing
#362 of 1,352

How does Atrium Companies, Inc. 8900/90/8000/1800/3900 Double Slider compare thermally against Window peers?

Atrium Companies, Inc. 8900/90/8000/1800/3900 Double Slider achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 8900/90/8000/1800/3900 Double SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 8900/90/8000/1800/3900 Double Slider (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

8900/90/8000/1800/3900 Double Slider Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 8900/90/8000/1800/3900 Double Slider is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.17-0.32.

Regional qualification covers Northern, North-Central, South-Central, Southern. 144 configurations meet ENERGY STAR Most Efficient criteria while 96 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.17 U-Factor yields 102.0 BTU/hr transfer (-30.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-10-03 licensing and 2025-02-27 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 474 certified glazing combinations for 8900/90/8000/1800/3900 Double Slider (NFRC ADW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 96 packages (41 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 144 packages (127 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 271 packages (127 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 474 packages (144 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Atrium Companies, Inc. produce?

Compare other active Atrium Companies, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Atrium Companies, Inc. 8900/90/8000/1800/3900 Double Slider appear below.

Where does Atrium Companies, Inc. 8900/90/8000/1800/3900 Double Slider stand thermally among ENERGY STAR Window lines?

Built with Vinyl framing in Dual-Slide Horizontal (HSXX) style, Atrium Companies, Inc. 8900/90/8000/1800/3900 Double Slider offers 474 Version 7.0 configurations from U 0.17 up to 0.32, posting -0.03 against the Window median of 0.20 with 144 Most Efficient picks.

Which glazing options in Atrium Companies, Inc. 8900/90/8000/1800/3900 Double Slider meet Northern climate limits?

Cold-climate buyers get 96 compliant Northern packages inside 8900/90/8000/1800/3900 Double Slider, reaching down to U 0.17. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

What BTU/hr heat transfer results from 8900/90/8000/1800/3900 Double Slider's 0.17 minimum U-Factor?

At U 0.17, a standard 3x5 ft (15 sq ft) 8900/90/8000/1800/3900 Double Slider opening transfers 102.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -30.0 BTU/hr difference.

When should a buyer skip Atrium Companies, Inc. 8900/90/8000/1800/3900 Double Slider and compare alternatives?

Skip 8900/90/8000/1800/3900 Double Slider if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 8900/90/8000/1800/3900 Double Slider options exceeding U 0.22.

Can you install Atrium Companies, Inc. 8900/90/8000/1800/3900 Double Slider in Southern or South-Central zones?

Warm-climate homeowners have 474 Southern-approved options within 8900/90/8000/1800/3900 Double Slider spanning SHGC down to 0.14. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

How many Atrium Companies, Inc. 8900/90/8000/1800/3900 Double Slider variants earn ENERGY STAR Most Efficient?

Not every package qualifies: 144 of 474 8900/90/8000/1800/3900 Double Slider glazing builds earn Most Efficient recognition (30.4%), while other variants sit on the standard Version 7.0 tier.

How do the 25C sunset and pre-1978 Lead RRP rules affect 8900/90/8000/1800/3900 Double Slider?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Atrium Companies, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How can homeowners confirm delivered Atrium Companies, Inc. 8900/90/8000/1800/3900 Double Slider units match permits?

Verify NFRC ID ADW and series ADW-M-389 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Atrium Companies, Inc. 8900/90/8000/1800/3900 Double Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros