Positioning #362/1,352 in certified Window, Kasson and Keller 700 / 7000 Series Casement pairs Vinyl frame construction with 296 glazing options rated between 0.16 and 0.42 SHGC across Northern, North-Central, South-Central, Southern. Across 14 certified Kasson and Keller product families, its thermal resistance spans 0.17 to 0.32 U-Factor and the line includes 111 ENERGY STAR Most Efficient packages (37.5% of line).

Min U-Factor
0.17
SHGC Range
0.16-0.42
Certified Options
296
Category Standing
#362 of 1,352

How does Kasson and Keller 700 / 7000 Series Casement compare thermally against Window peers?

Kasson and Keller 700 / 7000 Series Casement achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 700 / 7000 Series CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 700 / 7000 Series Casement (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

700 / 7000 Series Casement Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 700 / 7000 Series Casement is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.17-0.32.

Climate coverage for Kasson and Keller 700 / 7000 Series Casement spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 111 configurations meet ENERGY STAR Most Efficient criteria while 140 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 102.0 BTU/hr (-22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-30 and cert timestamp 2024-07-08.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 296 certified glazing combinations for 700 / 7000 Series Casement (NFRC KKI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 140 packages (3 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 235 packages (64 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 196 packages (61 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 220 packages (108 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Kasson and Keller produce?

Compare other active Kasson and Keller certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kasson and Keller 700 / 7000 Series Casement appear below.

What thermal performance numbers separate Kasson and Keller 700 / 7000 Series Casement from peers?

Kasson and Keller 700 / 7000 Series Casement spans 296 certified configurations with U-Factors between 0.17 and 0.32 and SHGC values from 0.16 to 0.42. Ranked #362 of 1,352 Window families, it carries 111 Most Efficient options.

Can homeowners install 700 / 7000 Series Casement in cold Northern ENERGY STAR counties?

Kasson and Keller 700 / 7000 Series Casement supplies 140 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

How do you calculate winter heat conduction for Kasson and Keller 700 / 7000 Series Casement?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 700 / 7000 Series Casement at U 0.17 conducts 102.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

When should a buyer skip Kasson and Keller 700 / 7000 Series Casement and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 700 / 7000 Series Casement options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

How many 700 / 7000 Series Casement glazing packages pass Southern solar-heat rules?

Exactly 220 700 / 7000 Series Casement options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.16 rather than higher 0.42 glass.

Are all 296 700 / 7000 Series Casement configurations ENERGY STAR Most Efficient?

Not every package qualifies: 111 of 296 700 / 7000 Series Casement glazing builds earn Most Efficient recognition (37.5%), while other variants sit on the standard Version 7.0 tier.

What federal compliance checks govern 2026 700 / 7000 Series Casement window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do you cross-check NFRC KKI and product line KKI-K-4 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code KKI and product line KKI-K-4, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kasson and Keller 700 / 7000 Series Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros