Window · Vinyl Frame NFRC KKI · Product Line KKI-K-5 ENERGY STAR Most Efficient Eligible

Kasson and Keller — 700 / 7000 Series Awning · Awning (Projected)

Positioning #362/1,352 in certified Window, Kasson and Keller 700 / 7000 Series Awning pairs Vinyl frame construction with 290 glazing options rated between 0.16 and 0.42 SHGC across Northern, North-Central, South-Central, Southern. Across 14 certified Kasson and Keller product families, its thermal resistance spans 0.17 to 0.32 U-Factor and the line includes 108 ENERGY STAR Most Efficient packages (37.2% of line).

Min U-Factor
0.17
SHGC Range
0.16-0.42
Certified Options
290
Category Standing
#362 of 1,352

How does Kasson and Keller 700 / 7000 Series Awning compare thermally against Window peers?

Kasson and Keller 700 / 7000 Series Awning achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 700 / 7000 Series AwningHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 700 / 7000 Series Awning (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

700 / 7000 Series Awning Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), 700 / 7000 Series Awning reaches 0.17 on its lowest-conductivity package — #271 of 1,009 in Vinyl, tied with 82 others at 0.17, more insulating than 65.0% of Vinyl lines, top 35.0% (-0.02 vs Vinyl peers). Pairing NFRC ID KKI across multi-pane fills shifts U-Factor from 0.32 down toward 0.17.

Mapping NFRC SHGC values (0.16 to 0.42) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 108 configurations meet ENERGY STAR Most Efficient criteria while 134 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.17 U-Factor yields 102.0 BTU/hr transfer (-30.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-01-30 licensing and 2024-04-19 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 290 certified glazing combinations for 700 / 7000 Series Awning (NFRC KKI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 134 packages (29 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 228 packages (61 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 194 packages (58 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 220 packages (105 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Kasson and Keller produce?

Compare other active Kasson and Keller certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kasson and Keller 700 / 7000 Series Awning appear below.

How efficient is Kasson and Keller 700 / 7000 Series Awning compared with peer Window models?

Built with Vinyl framing in Projected Awning (PRAW) style, Kasson and Keller 700 / 7000 Series Awning offers 290 Version 7.0 configurations from U 0.17 up to 0.32, posting -0.03 against the Window median of 0.20 with 108 Most Efficient picks.

How does Kasson and Keller 700 / 7000 Series Awning satisfy Version 7.0 Northern criteria?

Yes. 134 packages in Kasson and Keller 700 / 7000 Series Awning clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

How do you calculate winter heat conduction for Kasson and Keller 700 / 7000 Series Awning?

Using NFRC KKI U-Factor 0.17, a 15 sq ft Projected Awning (PRAW) assembly conducts 102.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-30.0 BTU/hr margin).

What homeowner profiles are a poor match for Kasson and Keller 700 / 7000 Series Awning?

Skip 700 / 7000 Series Awning if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 700 / 7000 Series Awning options exceeding U 0.22.

Does 700 / 7000 Series Awning meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 220 Southern-certified options inside Kasson and Keller 700 / 7000 Series Awning satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.42 SHGC on west-facing glass to avoid excess afternoon solar gain.

Are all 290 700 / 7000 Series Awning configurations ENERGY STAR Most Efficient?

Only 108 options out of 290 (37.2%) meet tighter Most Efficient U-Factor and SHGC thresholds in Kasson and Keller 700 / 7000 Series Awning, usually requiring triple-pane or upgraded Low-E coatings.

How do the 25C sunset and pre-1978 Lead RRP rules affect 700 / 7000 Series Awning?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 700 / 7000 Series Awning retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How can homeowners confirm delivered Kasson and Keller 700 / 7000 Series Awning units match permits?

Match the NFRC thermal sticker for code KKI and line KKI-K-5 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kasson and Keller 700 / 7000 Series Awning come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros