Kasson and Keller — 9100/910 Series RR/NC Single Hung · Single Hung
With a minimum U-Factor of 0.16—-0.04 compared against the 0.20 Window median—Kasson and Keller 9100/910 Series RR/NC Single Hung spans 97 tested options across Northern, North-Central, South-Central, Southern up to 0.26 U-Factor. Carrying NFRC CPD code KKI, the Vinyl assembly includes 32 ENERGY STAR Most Efficient packages (33.0% of line) and offers SHGC packages between 0.19 and 0.50.
- Min U-Factor
- 0.16
- SHGC Range
- 0.19-0.50
- Certified Options
- 97
- Category Standing
- #250 of 1,352
How does Kasson and Keller 9100/910 Series RR/NC Single Hung compare thermally against Window peers?
Kasson and Keller 9100/910 Series RR/NC Single Hung achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Kasson and Keller 9100/910 Series RR/NC Single Hung at rank #250 of 1,352 (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.19-0.50 band.
Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 32 configurations meet ENERGY STAR Most Efficient criteria while 52 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 96.0 BTU/hr (-27.3% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-30 and cert timestamp 2024-09-19.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 97 certified glazing combinations for 9100/910 Series RR/NC Single Hung (NFRC KKI) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 52 packages (30 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 78 packages (30 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 38 packages (17 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 38 packages (19 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| OKNA Windows & Doors Mfg — 800 Double Hung | Vinyl | 0.16 | 0.14 | 90 |
| OKNA Windows & Doors Mfg — 750-4750 Awning | Vinyl | 0.16 | 0.17 | 87 |
| OKNA Windows & Doors Mfg — CA700/4700 Casement | Vinyl | 0.16 | 0.14 | 111 |
| Mathews Brothers Company — Sanford Hills Bendable Picture Window | Vinyl | 0.16 | 0.23 | 81 |
| Ideal Window Manufacturing — Professional, Perfect Fit, Majestic, 3000, Platinum Picture Window | Vinyl | 0.16 | 0.19 | 78 |
What other certified series does Kasson and Keller produce?
Compare other active Kasson and Keller certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
700 / 7000 Series Picture Window
U-Factor 0.14–0.26 · 168 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kasson and Keller 9100/910 Series RR/NC Single Hung appear below.
How efficient is Kasson and Keller 9100/910 Series RR/NC Single Hung compared with peer Window models?
EPA ENERGY STAR v7.0 records 97 configurations for Kasson and Keller 9100/910 Series RR/NC Single Hung covering Northern, North-Central, South-Central, Southern, dropping down to U 0.16 versus a 0.20 Window median. Only 32 options earn Most Efficient status.
Can homeowners install 9100/910 Series RR/NC Single Hung in cold Northern ENERGY STAR counties?
Prescriptive Northern compliance covers 52 9100/910 Series RR/NC Single Hung packages (U floor 0.16, SHGC >= 0.17). Because the complete series stretches up to U 0.26, specify the cold-climate glass code explicitly.
What BTU/hr heat transfer results from 9100/910 Series RR/NC Single Hung's 0.16 minimum U-Factor?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 96.0 BTU/hr on 9100/910 Series RR/NC Single Hung's lowest-U package (0.16), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.26 transfer proportionally more energy.
What homeowner profiles are a poor match for Kasson and Keller 9100/910 Series RR/NC Single Hung?
Do not specify 9100/910 Series RR/NC Single Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 9100/910 Series RR/NC Single Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
Does 9100/910 Series RR/NC Single Hung meet Southern hot-climate SHGC caps (<= 0.23)?
Exactly 38 9100/910 Series RR/NC Single Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.19 rather than higher 0.50 glass.
Are all 97 9100/910 Series RR/NC Single Hung configurations ENERGY STAR Most Efficient?
Not every package qualifies: 32 of 97 9100/910 Series RR/NC Single Hung glazing builds earn Most Efficient recognition (33.0%), while other variants sit on the standard Version 7.0 tier.
Do 2026 9100/910 Series RR/NC Single Hung installations qualify for IRS Section 25C tax credits?
Any 9100/910 Series RR/NC Single Hung purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
How do you cross-check NFRC KKI and product line KKI-K-58 on delivery?
Confirm both the paper NFRC label and permanent corner glass etch match line KKI-K-58 and NFRC ID KKI before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Kasson and Keller 9100/910 Series RR/NC Single Hung come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)