Skip to main content
Window · Vinyl Frame NFRC KKI · Product Line KKI-K-58 ENERGY STAR Most Efficient Eligible

Kasson and Keller — 9100/910 Series RR/NC Single Hung · Single Hung

With a minimum U-Factor of 0.16—-0.04 compared against the 0.20 Window median—Kasson and Keller 9100/910 Series RR/NC Single Hung spans 97 tested options across Northern, North-Central, South-Central, Southern up to 0.26 U-Factor. Carrying NFRC CPD code KKI, the Vinyl assembly includes 32 ENERGY STAR Most Efficient packages (33.0% of line) and offers SHGC packages between 0.19 and 0.50.

Min U-Factor
0.16
SHGC Range
0.19-0.50
Certified Options
97
Category Standing
#250 of 1,352

How does Kasson and Keller 9100/910 Series RR/NC Single Hung compare thermally against Window peers?

Kasson and Keller 9100/910 Series RR/NC Single Hung achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 9100/910 Series RR/NC Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 9100/910 Series RR/NC Single Hung (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

9100/910 Series RR/NC Single Hung Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Kasson and Keller 9100/910 Series RR/NC Single Hung at rank #250 of 1,352 (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.19-0.50 band.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 32 configurations meet ENERGY STAR Most Efficient criteria while 52 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 96.0 BTU/hr (-27.3% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-30 and cert timestamp 2024-09-19.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 97 certified glazing combinations for 9100/910 Series RR/NC Single Hung (NFRC KKI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 52 packages (30 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 78 packages (30 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 38 packages (17 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 38 packages (19 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Kasson and Keller produce?

Compare other active Kasson and Keller certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kasson and Keller 9100/910 Series RR/NC Single Hung appear below.

How efficient is Kasson and Keller 9100/910 Series RR/NC Single Hung compared with peer Window models?

EPA ENERGY STAR v7.0 records 97 configurations for Kasson and Keller 9100/910 Series RR/NC Single Hung covering Northern, North-Central, South-Central, Southern, dropping down to U 0.16 versus a 0.20 Window median. Only 32 options earn Most Efficient status.

Can homeowners install 9100/910 Series RR/NC Single Hung in cold Northern ENERGY STAR counties?

Prescriptive Northern compliance covers 52 9100/910 Series RR/NC Single Hung packages (U floor 0.16, SHGC >= 0.17). Because the complete series stretches up to U 0.26, specify the cold-climate glass code explicitly.

What BTU/hr heat transfer results from 9100/910 Series RR/NC Single Hung's 0.16 minimum U-Factor?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 96.0 BTU/hr on 9100/910 Series RR/NC Single Hung's lowest-U package (0.16), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.26 transfer proportionally more energy.

What homeowner profiles are a poor match for Kasson and Keller 9100/910 Series RR/NC Single Hung?

Do not specify 9100/910 Series RR/NC Single Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 9100/910 Series RR/NC Single Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Does 9100/910 Series RR/NC Single Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Exactly 38 9100/910 Series RR/NC Single Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.19 rather than higher 0.50 glass.

Are all 97 9100/910 Series RR/NC Single Hung configurations ENERGY STAR Most Efficient?

Not every package qualifies: 32 of 97 9100/910 Series RR/NC Single Hung glazing builds earn Most Efficient recognition (33.0%), while other variants sit on the standard Version 7.0 tier.

Do 2026 9100/910 Series RR/NC Single Hung installations qualify for IRS Section 25C tax credits?

Any 9100/910 Series RR/NC Single Hung purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do you cross-check NFRC KKI and product line KKI-K-58 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line KKI-K-58 and NFRC ID KKI before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kasson and Keller 9100/910 Series RR/NC Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros