OKNA Windows & Doors Mfg — CA700/4700 Casement · Casement Windows
OKNA Windows & Doors Mfg CA700/4700 Casement is a Casement Windows assembly with a Vinyl frame that reaches a minimum U-Factor of 0.16 across 111 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #250 of 1,352 in Window, its thermal floor is 0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.14 to 0.25.
- Min U-Factor
- 0.16
- SHGC Range
- 0.14-0.25
- Certified Options
- 111
- Category Standing
- #250 of 1,352
How does OKNA Windows & Doors Mfg CA700/4700 Casement compare thermally against Window peers?
OKNA Windows & Doors Mfg CA700/4700 Casement achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 21 certified OKNA Windows & Doors Mfg series, this Casement Windows offers a 0.11 U-Factor adjustment span between 0.27 entry options and 0.16 top-performing glazing. Category standing is #250/1,352 (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%).
Climate coverage for OKNA Windows & Doors Mfg CA700/4700 Casement spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 48 configurations meet ENERGY STAR Most Efficient criteria while 24 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Registry history records EPA FENSTAR licensing on 2018-09-05 and v7.0 data certification on 2024-05-13. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.16 conducts 96.0 BTU/hr (-36.0 BTU/hr vs the 0.22 ceiling).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 111 certified glazing combinations for CA700/4700 Casement (NFRC OKW) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 24 packages (7 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 92 packages (42 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 104 packages (42 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 104 packages (48 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Kasson and Keller — 9200/920 Series RR/NC Double Hung | Vinyl | 0.16 | 0.19 | 99 |
| Kasson and Keller — 9100/910 Series RR/NC Single Hung | Vinyl | 0.16 | 0.19 | 97 |
| Vytex Corporation — 3300 Casement | Vinyl | 0.16 | 0.11 | 126 |
| Slocomb Windows and Doors, Inc — 300 Series Awning | Vinyl | 0.16 | 0.14 | 134 |
| Slocomb Windows and Doors, Inc — 300 Series Casement | Vinyl | 0.16 | 0.14 | 135 |
What other certified series does OKNA Windows & Doors Mfg produce?
Compare other active OKNA Windows & Doors Mfg certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to OKNA Windows & Doors Mfg CA700/4700 Casement appear below.
How well does CA700/4700 Casement by OKNA Windows & Doors Mfg insulate relative to Window benchmarks?
Built with Vinyl framing in Casement Single-Vent (CSSV) style, OKNA Windows & Doors Mfg CA700/4700 Casement offers 111 Version 7.0 configurations from U 0.16 up to 0.27, posting -0.04 against the Window median of 0.20 with 48 Most Efficient picks.
Is CA700/4700 Casement approved for Northern Zone heating climates?
Cold-climate buyers get 24 compliant Northern packages inside CA700/4700 Casement, reaching down to U 0.16. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.27 options.
How much winter heat loss does CA700/4700 Casement conduct across a 15 sq ft opening?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), CA700/4700 Casement at U 0.16 conducts 96.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
Which situations make CA700/4700 Casement the wrong window or door choice?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on CA700/4700 Casement options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.
How many CA700/4700 Casement glazing packages pass Southern solar-heat rules?
Yes. 104 Southern-certified options inside OKNA Windows & Doors Mfg CA700/4700 Casement satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.25 SHGC on west-facing glass to avoid excess afternoon solar gain.
Are all 111 CA700/4700 Casement configurations ENERGY STAR Most Efficient?
No. Exactly 48 of 111 configurations (43.2%) earn ENERGY STAR Most Efficient status in CA700/4700 Casement; the remaining standard v7.0 options pass base zone limits only.
What federal compliance checks govern 2026 CA700/4700 Casement window swaps?
Any CA700/4700 Casement purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
How do building inspectors verify CA700/4700 Casement glass specs on job sites?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code OKW and product line OKW-K-26, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for OKNA Windows & Doors Mfg CA700/4700 Casement come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)