Skip to main content
Window · Vinyl Frame NFRC KKI · Product Line KKI-K-57 ENERGY STAR Most Efficient Eligible

Kasson and Keller — 9200/920 Series RR/NC Double Hung · Double Hung

Kasson and Keller engineered the 9200/920 Series RR/NC Double Hung Double Hung line for Northern, North-Central, South-Central, Southern, certifying 99 glass-spacer combinations from 0.16 to 0.27 U-Factor and 0.19 to 0.48 SHGC. Relative to other Vinyl models tracked under NFRC KKI, its minimum U-Factor is 0.03 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.16
SHGC Range
0.19-0.48
Certified Options
99
Category Standing
#250 of 1,352

How does Kasson and Keller 9200/920 Series RR/NC Double Hung compare thermally against Window peers?

Kasson and Keller 9200/920 Series RR/NC Double Hung achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 9200/920 Series RR/NC Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 9200/920 Series RR/NC Double Hung (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

9200/920 Series RR/NC Double Hung Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Kasson and Keller 9200/920 Series RR/NC Double Hung at rank #250 of 1,352 (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.19-0.48 band.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 35 configurations meet ENERGY STAR Most Efficient criteria while 52 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-09-19 and FENSTAR license 2019-01-30 inside EPA Version 7.0 tables. Heat transfer computes to 96.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 99 certified glazing combinations for 9200/920 Series RR/NC Double Hung (NFRC KKI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 52 packages (30 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 79 packages (30 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 52 packages (22 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 52 packages (27 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Kasson and Keller produce?

Compare other active Kasson and Keller certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kasson and Keller 9200/920 Series RR/NC Double Hung appear below.

How well does 9200/920 Series RR/NC Double Hung by Kasson and Keller insulate relative to Window benchmarks?

Kasson and Keller 9200/920 Series RR/NC Double Hung spans 99 certified configurations with U-Factors between 0.16 and 0.27 and SHGC values from 0.19 to 0.48. Ranked #250 of 1,352 Window families, it carries 35 Most Efficient options.

How does Kasson and Keller 9200/920 Series RR/NC Double Hung satisfy Version 7.0 Northern criteria?

Yes. 52 packages in Kasson and Keller 9200/920 Series RR/NC Double Hung clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.27.

How much winter heat loss does 9200/920 Series RR/NC Double Hung conduct across a 15 sq ft opening?

Using NFRC KKI U-Factor 0.16, a 15 sq ft Double-Hung (VSDH) assembly conducts 96.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-36.0 BTU/hr margin).

What homeowner profiles are a poor match for Kasson and Keller 9200/920 Series RR/NC Double Hung?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 9200/920 Series RR/NC Double Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

What Southern ENERGY STAR v7.0 options exist in 9200/920 Series RR/NC Double Hung?

Across Northern, North-Central, South-Central, Southern, 52 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Kasson and Keller 9200/920 Series RR/NC Double Hung, while total line SHGC reaches 0.48 in colder packages.

Does 9200/920 Series RR/NC Double Hung carry EPA Most Efficient certification across its lineup?

Within 9200/920 Series RR/NC Double Hung, 35.4% (35 of 99) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

Do 2026 9200/920 Series RR/NC Double Hung installations qualify for IRS Section 25C tax credits?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Kasson and Keller upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How can homeowners confirm delivered Kasson and Keller 9200/920 Series RR/NC Double Hung units match permits?

Match the NFRC thermal sticker for code KKI and line KKI-K-57 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kasson and Keller 9200/920 Series RR/NC Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros