Kasson and Keller — 700 / 7000 Series Picture Window · Picture Window
Kasson and Keller engineered the 700 / 7000 Series Picture Window Picture Window line for Northern, North-Central, South-Central, Southern, certifying 168 glass-spacer combinations from 0.14 to 0.26 U-Factor and 0.18 to 0.51 SHGC. Relative to other Vinyl models tracked under NFRC KKI, its minimum U-Factor is 0.05 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.14
- SHGC Range
- 0.18-0.51
- Certified Options
- 168
- Category Standing
- #72 of 1,352
How does Kasson and Keller 700 / 7000 Series Picture Window compare thermally against Window peers?
Kasson and Keller 700 / 7000 Series Picture Window achieves a 0.14 thermal floor across Window lines, placing #72 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Kasson and Keller 700 / 7000 Series Picture Window standing at #72 of 1,352 certified Window product series, tied with 63 others at 0.14, more insulating than 90.0% of Window lines, top 10.0%. Comparing Vinyl profiles alone (median 0.19) shows -0.05 before selecting Low-E tiers.
Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 85 configurations meet ENERGY STAR Most Efficient criteria while 135 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.14 U-Factor yields 84.0 BTU/hr transfer (-48.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-01-30 licensing and 2024-11-04 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 168 certified glazing combinations for 700 / 7000 Series Picture Window (NFRC KKI) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 135 packages (70 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 131 packages (70 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 65 packages (56 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 65 packages (65 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| ProVia LLC — Wood Clad Vinyl Picture Window | Vinyl | 0.14 | 0.14 | 175 |
| Vinylbilt Windows and Doors 2021 Inc — Platinum/Diamond Low Fixed | Vinyl | 0.14 | 0.18 | 145 |
| OKNA Windows & Doors Mfg — PW 710/4710 | Vinyl | 0.14 | 0.15 | 96 |
| OKNA Windows & Doors Mfg — 7560 Casement | Vinyl | 0.14 | 0.15 | 76 |
| OKNA Windows & Doors Mfg — PW610-6610-510-5510 | Vinyl | 0.14 | 0.18 | 73 |
What other certified series does Kasson and Keller produce?
Compare other active Kasson and Keller certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kasson and Keller 700 / 7000 Series Picture Window appear below.
What U-Factor and SHGC range does Kasson and Keller 700 / 7000 Series Picture Window achieve?
Across 168 tested NFRC glazing configurations, Kasson and Keller 700 / 7000 Series Picture Window with Vinyl framing and Fixed Window (FIXD) style reaches a 0.14 minimum U-Factor and 0.18-0.51 SHGC band. It places #72 among 1,352 Window series—top 10.0%.
Which glazing options in Kasson and Keller 700 / 7000 Series Picture Window meet Northern climate limits?
Cold-climate buyers get 135 compliant Northern packages inside 700 / 7000 Series Picture Window, reaching down to U 0.14. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.26 options.
How does a 3x5 ft 700 / 7000 Series Picture Window window perform under a 40 deg F temperature drop?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.14 U-Factor yields 84.0 BTU/hr conductive transfer (-36.4% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
What homeowner profiles are a poor match for Kasson and Keller 700 / 7000 Series Picture Window?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 700 / 7000 Series Picture Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
Is 700 / 7000 Series Picture Window suitable for sunbelt cooling-dominated homes?
Yes, 700 / 7000 Series Picture Window holds 65 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.18 SHGC in cooling climates.
How many Kasson and Keller 700 / 7000 Series Picture Window variants earn ENERGY STAR Most Efficient?
EPA lists 85 Most Efficient options (50.6% share) inside Kasson and Keller 700 / 7000 Series Picture Window, out of 168 total Version 7.0 entries.
Do 2026 700 / 7000 Series Picture Window installations qualify for IRS Section 25C tax credits?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 700 / 7000 Series Picture Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
What permanent glass etch marks verify 700 / 7000 Series Picture Window after sticker removal?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code KKI and product line KKI-K-8, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Kasson and Keller 700 / 7000 Series Picture Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)