Skip to main content
Window · Vinyl Frame NFRC PEL · Product Line PEL-N-239 ENERGY STAR Most Efficient Eligible

Pella Corporation — 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement · Casement Windows

Pella Corporation engineered the 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement Casement Windows line for Northern, North-Central, South-Central, Southern, certifying 254 glass-spacer combinations from 0.17 to 0.32 U-Factor and 0.15 to 0.42 SHGC. Relative to other Vinyl models tracked under NFRC PEL, its minimum U-Factor is 0.02 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.17
SHGC Range
0.15-0.42
Certified Options
254
Category Standing
#362 of 1,352

How does Pella Corporation 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement compare thermally against Window peers?

Pella Corporation 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 39 certified Pella Corporation series, this Casement Windows offers a 0.15 U-Factor adjustment span between 0.32 entry options and 0.17 top-performing glazing. Category standing is #362/1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%).

Climate coverage for Pella Corporation 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 19 configurations meet ENERGY STAR Most Efficient criteria while 52 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-05-13 and FENSTAR license 2018-02-20 inside EPA Version 7.0 tables. Heat transfer computes to 102.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 254 certified glazing combinations for 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement (NFRC PEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 52 packages (1 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 86 packages (7 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 133 packages (7 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 212 packages (19 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Pella Corporation produce?

Compare other active Pella Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Pella Corporation 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement appear below.

What thermal performance numbers separate Pella Corporation 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement from peers?

Built with Vinyl framing in Casement Single-Vent (CSSV) style, Pella Corporation 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement offers 254 Version 7.0 configurations from U 0.17 up to 0.32, posting -0.03 against the Window median of 0.20 with 19 Most Efficient picks.

Is 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement approved for Northern Zone heating climates?

Pella Corporation 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement supplies 52 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

How do you calculate winter heat conduction for Pella Corporation 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement at U 0.17 conducts 102.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Who should NOT choose Pella Corporation 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement for a residential project?

Do not specify 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

What Southern ENERGY STAR v7.0 options exist in 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement?

Yes. 212 Southern-certified options inside Pella Corporation 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.42 SHGC on west-facing glass to avoid excess afternoon solar gain.

Are all 254 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement configurations ENERGY STAR Most Efficient?

EPA lists 19 Most Efficient options (7.5% share) inside Pella Corporation 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement, out of 254 total Version 7.0 entries.

Can homeowners claim Form 5695 credits on Pella Corporation 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

What permanent glass etch marks verify 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement after sticker removal?

Match the NFRC thermal sticker for code PEL and line PEL-N-239 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Pella Corporation 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros