Pella Corporation — 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement · Picture Window
Across 39 Pella Corporation certified families, 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement supplies 144 Picture Window configurations starting at 0.15 U-Factor and 0.18 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.51 SHGC. Its thermal floor ranks #136 of 1,352 category entries—0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.15
- SHGC Range
- 0.18-0.51
- Certified Options
- 144
- Category Standing
- #136 of 1,352
How does Pella Corporation 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement compare thermally against Window peers?
Pella Corporation 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Pella Corporation 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement at rank #136 of 1,352 (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.18-0.51 band.
Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 30 configurations meet ENERGY STAR Most Efficient criteria while 80 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Data provenance links certification 2024-05-13 and FENSTAR license 2018-02-20 inside EPA Version 7.0 tables. Heat transfer computes to 90.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 144 certified glazing combinations for 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement (NFRC PEL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 80 packages (10 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 48 packages (10 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 70 packages (8 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 96 packages (24 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Mercury Excelum, Inc. — EOS\EOS+\ICON Fixed Casement | Vinyl | 0.15 | 0.17 | 179 |
| Vinylbilt Windows and Doors 2021 Inc — Platinum/Diamond High Fixed | Vinyl | 0.15 | 0.16 | 179 |
| NT Window, Inc. — F150/G150 RR/NC Picture Window | Vinyl | 0.15 | 0.14 | 100 |
| NT Window, Inc. — F250/G250 RR/NC Picture Window | Vinyl | 0.15 | 0.14 | 94 |
| Mathews Brothers Company — Sanford Hills Awning | Vinyl | 0.15 | 0.15 | 195 |
What other certified series does Pella Corporation produce?
Compare other active Pella Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Pella Entry Doors - Wood Edge Steel Door
U-Factor 0.13–0.28 · 76,045 certified options.
250 Series / Power Symphony Fixed
U-Factor 0.14–0.32 · 266 certified options.
Architect Wood Fixed Casement
U-Factor 0.15–0.32 · 2,468 certified options.
Pella Entry Doors - Fiberglass Skin Door
U-Factor 0.15–0.28 · 242,982 certified options.
Pella Entry Doors - Fiberglass Skin Sidelite
U-Factor 0.15–0.28 · 319,127 certified options.
250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement
U-Factor 0.17–0.32 · 254 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Pella Corporation 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement appear below.
What U-Factor and SHGC range does Pella Corporation 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement achieve?
Across 144 tested NFRC glazing configurations, Pella Corporation 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement with Vinyl framing and Fixed Window (FIXD) style reaches a 0.15 minimum U-Factor and 0.18-0.51 SHGC band. It places #136 among 1,352 Window series—top 18.4%.
Can homeowners install 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement in cold Northern ENERGY STAR counties?
Cold-climate buyers get 80 compliant Northern packages inside 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement, reaching down to U 0.15. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.
How much winter heat loss does 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement conduct across a 15 sq ft opening?
Using NFRC PEL U-Factor 0.15, a 15 sq ft Fixed Window (FIXD) assembly conducts 90.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-42.0 BTU/hr margin).
Who should NOT choose Pella Corporation 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement for a residential project?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.
Is 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement suitable for sunbelt cooling-dominated homes?
Yes. 96 Southern-certified options inside Pella Corporation 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.51 SHGC on west-facing glass to avoid excess afternoon solar gain.
Are all 144 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement configurations ENERGY STAR Most Efficient?
Not every package qualifies: 30 of 144 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement glazing builds earn Most Efficient recognition (20.8%), while other variants sit on the standard Version 7.0 tier.
Do 2026 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement installations qualify for IRS Section 25C tax credits?
Any 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
Where are NFRC and IGCC identification marks located on 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement?
Inspectors match the temporary NFRC sticker (U 0.15-0.32, SHGC 0.18-0.51) against permit drawings for line PEL-N-240. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Pella Corporation 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)