Skip to main content
Window · Vinyl Frame NFRC ADW · Product Line ADW-M-407 ENERGY STAR Most Efficient Eligible

Atrium Companies, Inc. — 450/455/460/465 PW · Picture Window

Across 10 Atrium Companies, Inc. certified families, 450/455/460/465 PW supplies 579 Picture Window configurations starting at 0.21 U-Factor and 0.16 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.51 SHGC. Its thermal floor ranks #742 of 1,352 category entries—0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.21
SHGC Range
0.16-0.51
Certified Options
579
Category Standing
#742 of 1,352

How does Atrium Companies, Inc. 450/455/460/465 PW compare thermally against Window peers?

Atrium Companies, Inc. 450/455/460/465 PW achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 450/455/460/465 PWHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing 450/455/460/465 PW (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

450/455/460/465 PW Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 450/455/460/465 PW is 0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.21-0.32.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 83 configurations meet ENERGY STAR Most Efficient criteria while 188 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-12-20 and FENSTAR license 2018-10-03 inside EPA Version 7.0 tables. Heat transfer computes to 126.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 579 certified glazing combinations for 450/455/460/465 PW (NFRC ADW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 188 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 366 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 282 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 369 packages (83 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Krestmark Industries L. P. — 400/4000 PW Vinyl 0.21 0.19 576
A Window, Inc. — SL3 Series Picture Window (16059 Frame) Vinyl 0.21 0.18 575
A Window, Inc. — V-25 PW Vinyl 0.21 0.16 627
A Window, Inc. — V-31 PW Vinyl 0.21 0.16 627
Windsor Windows and Doors — Next Dimension Signature Radius and Direct Set Vinyl 0.21 0.13 518

What other certified series does Atrium Companies, Inc. produce?

Compare other active Atrium Companies, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Atrium Companies, Inc. 450/455/460/465 PW appear below.

What thermal performance numbers separate Atrium Companies, Inc. 450/455/460/465 PW from peers?

Atrium Companies, Inc. 450/455/460/465 PW spans 579 certified configurations with U-Factors between 0.21 and 0.32 and SHGC values from 0.16 to 0.51. Ranked #742 of 1,352 Window families, it carries 83 Most Efficient options.

How does Atrium Companies, Inc. 450/455/460/465 PW satisfy Version 7.0 Northern criteria?

Prescriptive Northern compliance covers 188 450/455/460/465 PW packages (U floor 0.21, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

What BTU/hr heat transfer results from 450/455/460/465 PW's 0.21 minimum U-Factor?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 126.0 BTU/hr on 450/455/460/465 PW's lowest-U package (0.21), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

What are the practical limitations of specifying 450/455/460/465 PW?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 450/455/460/465 PW options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is 450/455/460/465 PW suitable for sunbelt cooling-dominated homes?

Yes, 450/455/460/465 PW holds 369 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.16 SHGC in cooling climates.

Which package tier in 450/455/460/465 PW holds Most Efficient recognition?

Within 450/455/460/465 PW, 14.3% (83 of 579) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

How do the 25C sunset and pre-1978 Lead RRP rules affect 450/455/460/465 PW?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Atrium Companies, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

What permanent glass etch marks verify 450/455/460/465 PW after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line ADW-M-407 and NFRC ID ADW before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Atrium Companies, Inc. 450/455/460/465 PW come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros