Skip to main content
Window · Vinyl Frame NFRC ADW · Product Line ADW-M-388 ENERGY STAR Most Efficient Eligible

Atrium Companies, Inc. — 8900/3900/625/25 Double Hung · Double Hung

Atrium Companies, Inc. 8900/3900/625/25 Double Hung is a Double Hung assembly with a Vinyl frame that reaches a minimum U-Factor of 0.17 across 474 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #362 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.14 to 0.23.

Min U-Factor
0.17
SHGC Range
0.14-0.23
Certified Options
474
Category Standing
#362 of 1,352

How does Atrium Companies, Inc. 8900/3900/625/25 Double Hung compare thermally against Window peers?

Atrium Companies, Inc. 8900/3900/625/25 Double Hung achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 8900/3900/625/25 Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 8900/3900/625/25 Double Hung (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

8900/3900/625/25 Double Hung Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 10 certified Atrium Companies, Inc. series, this Double Hung offers a 0.15 U-Factor adjustment span between 0.32 entry options and 0.17 top-performing glazing. Category standing is #362/1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%).

Regional qualification covers Northern, North-Central, South-Central, Southern. 143 configurations meet ENERGY STAR Most Efficient criteria while 96 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-10-03 and v7.0 data certification on 2025-09-25. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.17 conducts 102.0 BTU/hr (-30.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 474 certified glazing combinations for 8900/3900/625/25 Double Hung (NFRC ADW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 96 packages (37 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 144 packages (120 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 280 packages (120 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 474 packages (143 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Atrium Companies, Inc. produce?

Compare other active Atrium Companies, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Atrium Companies, Inc. 8900/3900/625/25 Double Hung appear below.

How efficient is Atrium Companies, Inc. 8900/3900/625/25 Double Hung compared with peer Window models?

Atrium Companies, Inc. 8900/3900/625/25 Double Hung spans 474 certified configurations with U-Factors between 0.17 and 0.32 and SHGC values from 0.14 to 0.23. Ranked #362 of 1,352 Window families, it carries 143 Most Efficient options.

Is 8900/3900/625/25 Double Hung approved for Northern Zone heating climates?

Cold-climate buyers get 96 compliant Northern packages inside 8900/3900/625/25 Double Hung, reaching down to U 0.17. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

How does a 3x5 ft 8900/3900/625/25 Double Hung window perform under a 40 deg F temperature drop?

Using NFRC ADW U-Factor 0.17, a 15 sq ft Double-Hung (VSDH) assembly conducts 102.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-30.0 BTU/hr margin).

Which situations make 8900/3900/625/25 Double Hung the wrong window or door choice?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 8900/3900/625/25 Double Hung options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

How many 8900/3900/625/25 Double Hung glazing packages pass Southern solar-heat rules?

Yes. 474 Southern-certified options inside Atrium Companies, Inc. 8900/3900/625/25 Double Hung satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.23 SHGC on west-facing glass to avoid excess afternoon solar gain.

Which package tier in 8900/3900/625/25 Double Hung holds Most Efficient recognition?

Not every package qualifies: 143 of 474 8900/3900/625/25 Double Hung glazing builds earn Most Efficient recognition (30.2%), while other variants sit on the standard Version 7.0 tier.

What 2026 federal tax credit and Lead RRP rules apply to 8900/3900/625/25 Double Hung?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 8900/3900/625/25 Double Hung retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How can homeowners confirm delivered Atrium Companies, Inc. 8900/3900/625/25 Double Hung units match permits?

Inspectors match the temporary NFRC sticker (U 0.17-0.32, SHGC 0.14-0.23) against permit drawings for line ADW-M-388. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Atrium Companies, Inc. 8900/3900/625/25 Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros