Skip to main content
Window · Vinyl Frame NFRC AWN · Product Line AWN-M-7

A Window, Inc. — V-25/31 SS · Single Slider

Positioning #1,034/1,352 in certified Window, A Window, Inc. V-25/31 SS pairs Vinyl frame construction with 970 glazing options rated between 0.15 and 0.30 SHGC across North-Central, South-Central, Southern. Across 10 certified A Window, Inc. product families, its thermal resistance spans 0.24 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.24
SHGC Range
0.15-0.30
Certified Options
970
Category Standing
#1,034 of 1,352

How does A Window, Inc. V-25/31 SS compare thermally against Window peers?

A Window, Inc. V-25/31 SS achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. V-25/31 SSHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing V-25/31 SS (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

V-25/31 SS Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across V-25/31 SS spans 970 NFRC test records (AWN), ranking #1,034 of 1,352 Window families (tied with 139 others at 0.24, more insulating than 13.2% of Window lines). Its 0.24 thermal floor compares at +0.05 against the Vinyl median (0.19).

Climate coverage for A Window, Inc. V-25/31 SS spans North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.15 lowers cooling load.

Lifecycle documentation anchors AWN to 2024-07-08 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 144.0 BTU/hr conductive loss (+9.1% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 970 certified glazing combinations for V-25/31 SS (NFRC AWN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 206 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 516 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 934 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
YKK AP America, Inc. — Precedence Horizontal Slider Vinyl 0.24 0.18 884
Seaway Manufacturing Corporation — Amerivu Single Hung Vinyl 0.24 0.13 1,062
Amsco Windows — V2K Basement Window Vinyl 0.24 0.13 1,114
Atrium Companies, Inc. — 450/455/460/465 DH Vinyl 0.24 0.15 805
YKK AP America, Inc. — Style View Single Slider Vinyl 0.24 0.19 803

What other certified series does A Window, Inc. produce?

Compare other active A Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to A Window, Inc. V-25/31 SS appear below.

What thermal performance numbers separate A Window, Inc. V-25/31 SS from peers?

A Window, Inc. V-25/31 SS spans 970 certified configurations with U-Factors between 0.24 and 0.32 and SHGC values from 0.15 to 0.30. Ranked #1,034 of 1,352 Window families, it carries 0 Most Efficient options.

Which glazing options in A Window, Inc. V-25/31 SS meet Northern climate limits?

A Window, Inc. V-25/31 SS holds zero Northern Zone qualifications (min U 0.24). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

How much winter heat loss does V-25/31 SS conduct across a 15 sq ft opening?

Using NFRC AWN U-Factor 0.24, a 15 sq ft Horizontal Slider (HSOX) assembly conducts 144.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+12.0 BTU/hr margin).

Which situations make V-25/31 SS the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on V-25/31 SS options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

How many V-25/31 SS glazing packages pass Southern solar-heat rules?

Yes, V-25/31 SS holds 934 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.15 SHGC in cooling climates.

What glazing share inside V-25/31 SS qualifies as Most Efficient?

Zero glazing builds inside V-25/31 SS's 970 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

Do 2026 V-25/31 SS installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 V-25/31 SS installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

What permanent glass etch marks verify V-25/31 SS after sticker removal?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code AWN and product line AWN-M-7, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for A Window, Inc. V-25/31 SS come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros