A Window, Inc. — V-25/31 SS · Single Slider
Positioning #1,034/1,352 in certified Window, A Window, Inc. V-25/31 SS pairs Vinyl frame construction with 970 glazing options rated between 0.15 and 0.30 SHGC across North-Central, South-Central, Southern. Across 10 certified A Window, Inc. product families, its thermal resistance spans 0.24 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.
- Min U-Factor
- 0.24
- SHGC Range
- 0.15-0.30
- Certified Options
- 970
- Category Standing
- #1,034 of 1,352
How does A Window, Inc. V-25/31 SS compare thermally against Window peers?
A Window, Inc. V-25/31 SS achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across V-25/31 SS spans 970 NFRC test records (AWN), ranking #1,034 of 1,352 Window families (tied with 139 others at 0.24, more insulating than 13.2% of Window lines). Its 0.24 thermal floor compares at +0.05 against the Vinyl median (0.19).
Climate coverage for A Window, Inc. V-25/31 SS spans North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.15 lowers cooling load.
Lifecycle documentation anchors AWN to 2024-07-08 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 144.0 BTU/hr conductive loss (+9.1% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 970 certified glazing combinations for V-25/31 SS (NFRC AWN) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 206 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 516 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 934 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| YKK AP America, Inc. — Precedence Horizontal Slider | Vinyl | 0.24 | 0.18 | 884 |
| Seaway Manufacturing Corporation — Amerivu Single Hung | Vinyl | 0.24 | 0.13 | 1,062 |
| Amsco Windows — V2K Basement Window | Vinyl | 0.24 | 0.13 | 1,114 |
| Atrium Companies, Inc. — 450/455/460/465 DH | Vinyl | 0.24 | 0.15 | 805 |
| YKK AP America, Inc. — Style View Single Slider | Vinyl | 0.24 | 0.19 | 803 |
What other certified series does A Window, Inc. produce?
Compare other active A Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
SL3 Series Picture Window (15997 Frame)
U-Factor 0.21–0.32 · 477 certified options.
SL3 Series Picture Window (16059 Frame)
U-Factor 0.21–0.32 · 575 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to A Window, Inc. V-25/31 SS appear below.
What thermal performance numbers separate A Window, Inc. V-25/31 SS from peers?
A Window, Inc. V-25/31 SS spans 970 certified configurations with U-Factors between 0.24 and 0.32 and SHGC values from 0.15 to 0.30. Ranked #1,034 of 1,352 Window families, it carries 0 Most Efficient options.
Which glazing options in A Window, Inc. V-25/31 SS meet Northern climate limits?
A Window, Inc. V-25/31 SS holds zero Northern Zone qualifications (min U 0.24). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.
How much winter heat loss does V-25/31 SS conduct across a 15 sq ft opening?
Using NFRC AWN U-Factor 0.24, a 15 sq ft Horizontal Slider (HSOX) assembly conducts 144.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+12.0 BTU/hr margin).
Which situations make V-25/31 SS the wrong window or door choice?
Cold-climate owners needing prescriptive U <= 0.22 should pass on V-25/31 SS options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
How many V-25/31 SS glazing packages pass Southern solar-heat rules?
Yes, V-25/31 SS holds 934 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.15 SHGC in cooling climates.
What glazing share inside V-25/31 SS qualifies as Most Efficient?
Zero glazing builds inside V-25/31 SS's 970 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.
Do 2026 V-25/31 SS installations qualify for IRS Section 25C tax credits?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 V-25/31 SS installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
What permanent glass etch marks verify V-25/31 SS after sticker removal?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code AWN and product line AWN-M-7, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for A Window, Inc. V-25/31 SS come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)