Skip to main content
Window · Vinyl Frame NFRC AMS · Product Line AMS-A-21

Amsco Windows — V2K Basement Window · Single Slider

Across 12 Amsco Windows certified families, V2K Basement Window supplies 1,114 Single Slider configurations starting at 0.24 U-Factor and 0.13 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.51 SHGC. Its thermal floor ranks #1,034 of 1,352 category entries—0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.24
SHGC Range
0.13-0.51
Certified Options
1,114
Category Standing
#1,034 of 1,352

How does Amsco Windows V2K Basement Window compare thermally against Window peers?

Amsco Windows V2K Basement Window achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. V2K Basement WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing V2K Basement Window (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

V2K Basement Window Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Amsco Windows V2K Basement Window standing at #1,034 of 1,352 certified Window product series, tied with 139 others at 0.24, more insulating than 13.2% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.05 before selecting Low-E tiers.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 25 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors AMS to 2025-01-30 certification (FENSTAR issued 2018-10-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 144.0 BTU/hr conductive loss (+9.1% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,114 certified glazing combinations for V2K Basement Window (NFRC AMS) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 25 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 165 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 449 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 1,035 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Seaway Manufacturing Corporation — Amerivu Single Hung Vinyl 0.24 0.13 1,062
YKK AP America, Inc. — Precedence / Style View / Style Guard Awning Window Vinyl 0.24 0.17 1,237
A Window, Inc. — V-25/31 SH Vinyl 0.24 0.15 980
A Window, Inc. — V-25/31 SS Vinyl 0.24 0.15 970
Seaway Manufacturing Corporation — Amerivu Single Slider Vinyl 0.24 0.13 1,264

What other certified series does Amsco Windows produce?

Compare other active Amsco Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Amsco Windows V2K Basement Window appear below.

How efficient is Amsco Windows V2K Basement Window compared with peer Window models?

Amsco Windows V2K Basement Window spans 1,114 certified configurations with U-Factors between 0.24 and 0.32 and SHGC values from 0.13 to 0.51. Ranked #1,034 of 1,352 Window families, it carries 0 Most Efficient options.

Which glazing options in Amsco Windows V2K Basement Window meet Northern climate limits?

With a 0.24 minimum U-Factor, Amsco Windows V2K Basement Window cannot satisfy prescriptive <= 0.22 Northern targets, yet 25 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

How do you calculate winter heat conduction for Amsco Windows V2K Basement Window?

At U 0.24, a standard 3x5 ft (15 sq ft) V2K Basement Window opening transfers 144.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +12.0 BTU/hr difference.

Who should NOT choose Amsco Windows V2K Basement Window for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on V2K Basement Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Does V2K Basement Window meet Southern hot-climate SHGC caps (<= 0.23)?

Across Northern, North-Central, South-Central, Southern, 1,035 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Amsco Windows V2K Basement Window, while total line SHGC reaches 0.51 in colder packages.

What glazing share inside V2K Basement Window qualifies as Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 1,114 V2K Basement Window options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

How do the 25C sunset and pre-1978 Lead RRP rules affect V2K Basement Window?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current V2K Basement Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do you cross-check NFRC AMS and product line AMS-A-21 on delivery?

Match the NFRC thermal sticker for code AMS and line AMS-A-21 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Amsco Windows V2K Basement Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros