Skip to main content
Window · Vinyl Frame NFRC YKK · Product Line YKK-A-12

YKK AP America, Inc. — Precedence / Style View / Style Guard Awning Window · Awning (Projected)

YKK AP America, Inc. Precedence / Style View / Style Guard Awning Window is a Awning, Projected assembly with a Vinyl frame that reaches a minimum U-Factor of 0.24 across 1,237 certified glazing configurations covering North-Central, South-Central, Southern. Ranked #1,034 of 1,352 in Window, its thermal floor is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.17 to 0.26.

Min U-Factor
0.24
SHGC Range
0.17-0.26
Certified Options
1,237
Category Standing
#1,034 of 1,352

How does YKK AP America, Inc. Precedence / Style View / Style Guard Awning Window compare thermally against Window peers?

YKK AP America, Inc. Precedence / Style View / Style Guard Awning Window achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Precedence / Style View / Style Guard Awning WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Precedence / Style View / Style Guard Awning Window (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Precedence / Style View / Style Guard Awning Window Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows YKK AP America, Inc. Precedence / Style View / Style Guard Awning Window standing at #1,034 of 1,352 certified Window product series, tied with 139 others at 0.24, more insulating than 13.2% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.05 before selecting Low-E tiers.

Mapping NFRC SHGC values (0.17 to 0.26) against ENERGY STAR Version 7.0 targets approves North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.17 lowers cooling load.

Registry history records EPA FENSTAR licensing on 2019-01-31 and v7.0 data certification on 2025-03-12. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.24 conducts 144.0 BTU/hr (+12.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,237 certified glazing combinations for Precedence / Style View / Style Guard Awning Window (NFRC YKK) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 154 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 562 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 1,201 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does YKK AP America, Inc. produce?

Compare other active YKK AP America, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to YKK AP America, Inc. Precedence / Style View / Style Guard Awning Window appear below.

What thermal performance numbers separate YKK AP America, Inc. Precedence / Style View / Style Guard Awning Window from peers?

Across 1,237 tested NFRC glazing configurations, YKK AP America, Inc. Precedence / Style View / Style Guard Awning Window with Vinyl framing and Projected Awning (PRAW) style reaches a 0.24 minimum U-Factor and 0.17-0.26 SHGC band. It places #1,034 among 1,352 Window series—more insulating than 13.2%.

Which glazing options in YKK AP America, Inc. Precedence / Style View / Style Guard Awning Window meet Northern climate limits?

This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.24). Focus on North-Central, South-Central, Southern glazing applications where SHGC 0.17-0.26 manages cooling loads.

What conductive BTU/hr difference separates Precedence / Style View / Style Guard Awning Window from the 0.22 Northern rule?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 144.0 BTU/hr on Precedence / Style View / Style Guard Awning Window's lowest-U package (0.24), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

Who should NOT choose YKK AP America, Inc. Precedence / Style View / Style Guard Awning Window for a residential project?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Precedence / Style View / Style Guard Awning Window options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Can you install YKK AP America, Inc. Precedence / Style View / Style Guard Awning Window in Southern or South-Central zones?

Yes. 1,201 Southern-certified options inside YKK AP America, Inc. Precedence / Style View / Style Guard Awning Window satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.26 SHGC on west-facing glass to avoid excess afternoon solar gain.

Which package tier in Precedence / Style View / Style Guard Awning Window holds Most Efficient recognition?

Zero glazing builds inside Precedence / Style View / Style Guard Awning Window's 1,237 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

Can homeowners claim Form 5695 credits on YKK AP America, Inc. Precedence / Style View / Style Guard Awning Window in 2026?

Any Precedence / Style View / Style Guard Awning Window purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do building inspectors verify Precedence / Style View / Style Guard Awning Window glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line YKK-A-12 and NFRC ID YKK before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for YKK AP America, Inc. Precedence / Style View / Style Guard Awning Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros